Operations 16
Operations
In this section
Power up the server................................................................................................................................ 16
Power down the server............................................................................................................................ 16
Extend the server from the rack ................................................................................................................ 17
Remove the server from the rack............................................................................................................... 17
Remove the access panel ........................................................................................................................ 17
Remove the PCI riser board assembly ....................................................................................................... 18
Install the PCI riser board assembly .......................................................................................................... 18
Remove the fan assembly ........................................................................................................................ 19
Install the fan assembly ........................................................................................................................... 20
Remove the BBWC battery holder ............................................................................................................ 21
Power up the server
To power up the server, press the Power On/Standby button.
Power down the server
WARNING: To reduce the risk of personal injury, electric shock, or damage to the
equipment, remove the power cord to remove power from the server. The front panel
Power On/Standby button does not completely shut off system power. Portions of the
power supply and some internal circuitry remain active until AC power is removed.
IMPORTANT:
If installing a hot-plug device, it is not necessary to power down the server.
1.
Back up the server data.
2.
Shut down the operating system as directed by the operating system documentation.
NOTE:
If the operating system automatically places the server in Standby mode, omit the next step.
3.
Press the Power On/Standby button to place the server in Standby mode. When the server activates
Standby power mode, the system power LED changes to amber.
IMPORTANT:
Pressing the UID button illuminates the blue UID LEDs on the front or rear panels. In a rack
environment, this feature facilitates locating a server when moving between the front and rear of the rack.
4.
Disconnect the power cords.
The system is now without power.
Summary of Contents for ProLiant DL320 Generation 5
Page 15: ...Component identification 15 Fan assembly location ...
Page 52: ...Cabling 52 Slot 1 Video connector option cable routing ...
Page 53: ...Cabling 53 Battery backed write cache cable routing ...
Page 71: ...Troubleshooting 71 ...
Page 94: ...Technical support 94 ...
Page 95: ...Technical support 95 ...