background image

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).

Idle

 

LWAd

6.30 B

LpAm

52.07dBA

Operating

 

LWAd

6.38 B

LpAm

52.77 dBA

Power Supply

Input voltage
specifications

Rated input voltage

100 VAC to 240 VAC

Input Specifications

Rated input line

90 VAC to 264VAC

Frequency range

47 to 63 Hz

Rated input power

@ 115V input, Rated input power = 486W
(assume output wattage=450W
@ 230V input, Rated input power = 479W
(assume output wattage=450W)

Rated input current

6 A, 3 A (110 V, 220 V)

Steady state power

420W (rated)

BTU Rating

1710 BTU/hr

 

Ambient temperature
range

Operating

50° to 118° F (10° to 48° C)

Non-operating

-40° to 158° F (-40° to 70° C)

Relative humidity

(non-condensing)

Operating

55% to 85%

Non-operating

5% to 95%

Dielectric voltage
withstand

Input to output

1800 VAC/minute

Input to ground

1800 VAC/minute

Maximum Wet Bulb
Temperature

106.3° F (41.3° C)

 

QuickSpecs

HP ProLiant DL320 Generation 5p

Technical Specifications

DA - 12854   Worldwide QuickSpecs — Version 12 — 5-28-2008

Page 36

Summary of Contents for ProLiant DL320 G5

Page 1: ...uad Core Intel Xeon processors with up to 12 MB L2 cache for 1333MHz Front Side Bus Support for low cost Intel Celeron 440 processor At a Glance The HP ProLiant DL320 G5p Server is an enterprise rack optimized server at an entry level price The highly manageable 1 processor 1U server is ideal for single application IT infrastructure web and edge of network applications The remote console and virtu...

Page 2: ...ss x8 slot x8 connector Can be replaced with a full length 64 bit 133MHz PCI X slot 1 Half length low profile PCI Express x1 slot x8 connector USB 2 0 Ports Up to 5 Total 2 front 1 internal optional 2 rear accessible ports Internal USB port optional for flexible storage security or USB drive key deployment Management HP Insight Control Environment server management software Integrated Lights Out 2...

Page 3: ...rives have a one year warranty NOTE Server Warranty includes three year parts one year labor and one year on site support with next business day response Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html QuickSpecs HP ProLiant DL320 Generation 5p Overview DA 12854 Worldwide QuickS...

Page 4: ...z 4MB L2 Cache 65 Watts 1333MHz FSB NOTE Available via CTO only Dual Core Intel Core 2 processor E4600 2 4GHz 2MB L2 cache 800MHz FSB NOTE Available via CTO only Dual Core Intel Core 2 processor E4400 2 0GHz 2MB L2 cache 800MHz FSB NOTE Available via CTO only Dual Core Intel Pentium processor E2160 1 80GHz 1MB L2 cache 800MHz FSB NOTE Available via CTO only Single Core Intel Celeron processor 440 ...

Page 5: ...ull height slot Default bus assignment in decimal Inserting cards with PCI bridges may alter the actual bus assignment number Slots are enumerated differently based on OS MS OS s enumerate from lowest to highest Device ID by bus starting with the lowest bus Indicates the number of physical electrical lanes running to a PCI e connector Storage Controllers Integrated Intel 82801IR Serial ATA Host Co...

Page 6: ...ional information regarding USB support http h18004 www1 hp com products servers platforms usb support html Graphics 1 rear Keyboard 1 Mouse 1 Network RJ 45 2 NIC 1 shared iLO 2 port Dedicated iLO 2 remote management port 1 optional Graphics Integrated ATI ES1000 32 MB video standard 16 bit color maximum resolution of 1600 x 1200 32 bit color maximum resolution of 1280 x 1024 NOTE Maximum resoluti...

Page 7: ...HP Insight Control management suites and most HP ProLiant Essentials include a one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates For more information about this service please visit http www hp com services insight Server Management Stand Alone Software Product ProLiant Essentials HP Systems Insi...

Page 8: ...Start Web site at http www hp com servers smartstart SmartStart version supported minimum SmartStart 7 90 Insight Management Agents The Insight Management Agents should be installed on all HP servers to present system instrumentation health and configuration information into HP Systems Insight Manager and the HP System Management Homepage The HP System Management Homepage aggregates systems data f...

Page 9: ...izes software RAID mirroring for data replication and is storage array independent HP StorageWorks XP EVA Cluster Extension Software for Linux CLX works seamlessly with HP Serviceguard for Linux HP StorageWorks Continuous Access and HP Disk Arrays to automate failover and failback between sites Software updates are distributed by HP Services to customers with support contracts NOTE For additional ...

Page 10: ...assword Keyboard password USB Port control Removable optical drive assembly optional Removable DVD ROM Drive Assembly optional Dedicated iLO2 port optional Administrator s password Server Power Cords North America One 6 Highline IEC IEC power cord ships standard Japan One 6 Highline IEC power cord and one 6 Lowline power cord ship standard ROW One 6 Highline IEC power cord ships standard NOTE HP P...

Page 11: ...mation on how to buy server operating systems from HP please visit the OS product site at http h18004 www1 hp com products servers software OEM html Rack Airflow Requirements Rack 10000 series Cabinets The increasing power of new high performance processor technology requires increased cooling efficiency for rack mounted servers The 10000 Series Racks provide enhanced airflow for maximum cooling a...

Page 12: ...e or afterward and internal to the enclosure It also includes the 22 inch and smaller external monitors and tower UPS options up to 3kVA These items will be covered at the same service level and for the same coverage period as the server Coverage of UPS Battery is not included and standard warranty terms conditions apply For servers or storage systems installed within a rack service also covers al...

Page 13: ...imum of ECC PC2 6400 Unbuffered DDR2 SDRAM Memory Network Controller Embedded NC326i Dual Port Gigabit Server Adapter Storage Controller Intel 82801IR Integrated Serial ATA Host Controller Hard Drives None ship standard Internal Storage SAS 1 2TB maximum SATA 3 0TB maximum NOTE SAS requires optional PCI Controller Optical Drive Optional Power Supply Auto sensing 400 Watt PFC Power Supply CE Mark C...

Page 14: ...Intel 82801IR Integrated Serial ATA Host Controller Hard Drives None ship standard Internal Storage SAS 1 2TB maximum SATA 3 0TB maximum NOTE SAS requires optional PCI Controller Optical Drive Optional Power Supply Auto sensing 400 Watt PFC Power Supply CE Mark Compliant Form Factor Rack 1U 1 70 in 4 32 cm Country Code Key xx 00 North America xx 29 Japan xx 37 APD Asia excluding Japan xx 42 EURO E...

Page 15: ... Fixed mounting rails Step 2 Choose Required Options only one of the following from each list unless otherwise noted Processors Intel Celeron 420 processor FIO Kit 450125 L21 Intel Celeron 440 processor FIO Kit 468963 L21 Dual Core Intel Pentium E2160 Processor FIO Kit 455035 L21 Dual Core Intel Core E4400 processor FIO Kit 455033 L21 Dual Core Intel Core E4600 processor FIO Kit 482110 L21 Dual Co...

Page 16: ...Smart Array E200 128 BBWC Controller 411508 B21 HP Smart Array P400 256MB Controller 405132 B21 HP Smart Array P400 512MB BBWC Controller 411064 B21 HP Smart Array E500 256MB Controller 435129 B21 HP Smart Array P800 512MB BBWC Controller 381513 B21 NOTE Any Smart Array Controller CTO purchase automatically includes the HP HBA SAS SATA 4x1LN Cable Kit 452130 B21 452130 B21 QuickSpecs HP ProLiant D...

Page 17: ...ontrol Management DVD media without licenses Contains Insight Manager and Essentials software products and components licensed by Insight Control Management suites Uses an integrated installer to perform quick and accurate software installation and updates 436222 B21 NOTE For additional License Kits please see the QuickSpecs at http h18000 www1 hp com products quickspecs 12631_div 12631_div html H...

Page 18: ...dates NOTE This license allows 1 physical to virtual or virtual to virtual migration Customer will receive a printed license entitlement certificate and documentation via physical shipment The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key s Includes one year of 24 x 7 HP Software Technical Support and Update Service 460753 B21 HP S...

Page 19: ...pported on 4HDD models 451688 B21 DL320G5p DVD ROM Drive 12 7mm NOTE Only supported on 2HDD models 449991 B21 DL320G5p DVD RW Drive 12 7mm NOTE Only supported on 2HDD models 449998 B21 Hard Drives Hot Plug SAS 3 5 Drives HP 300GB 3G SAS 15K 3 5 SP HDD 431944 B21 HP 300GB 3G SAS 15K 3 5 DP HDD 416127 B21 HP 146GB 3G SAS 15K 3 5 SP HDD 375872 B21 HP 146GB 3G SAS 15K 3 5 DP HDD 384854 B21 HP 72GB 3G ...

Page 20: ...e factory For all solutions please refer to the server QuickSpecs and User s Manual for detailed installation instructions 417836 B21 Battery backed write cache upgrade NOTE Battery only For Smart Array P400 Controller only 383280 B21 512MB Battery backed write cache upgrade NOTE For Smart Array P400 Controller only 405148 B21 HP ProLiant P800 Controller HP Smart Array P800 512MB BBWC Controller 3...

Page 21: ...iv html Smart Array 642 http h18000 www1 hp com products quickspecs 11943_div 11943_div html HP Single Channel Ultra320 SCSI HBA http h18000 www1 hp com products quickspecs 12566_div 12566_div html SC11Xe HBA Communications HP NC110T PCI Express Gigabit Server Adapter 434905 B21 HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648 B21 HP NC364T PCI Express Quad Port Gigabit Server Adapter...

Page 22: ...rs media and other related items http h18006 www1 hp com products quickspecs 11739_div 11739_div html Worldwide http h18006 www1 hp com products quickspecs 12128_div 12128_div html Worldwide For an up to date listing of the latest O S and software support details for HP Ultrium tape drives please visit http www hp com go connect Rack Mount Tape Drive Enclosures HP StorageWorks 1U SCSI Rack Mount K...

Page 23: ...h18000 www1 hp com products quickspecs 12651_div 12651_div html Tape Autoloaders HP StorageWorks DAT Autoloader HP StorageWorks DAT 72x10 tape autoloader AE313B HP StorageWorks 1 8 Tape Autoloader HP StorageWorks 1 8 G2 LTO 4 Ultrium 1760 SAS Tape Autoloader AK377A HP StorageWorks 1 8 G2 LTO 3 Ultrium 920 Tape Autoloader AH165A HP StorageWorks 1 8 G2 LTO 3 Ultrium 920 SAS Autoloader AH558A HP Stor...

Page 24: ...additional information needed to create a complete solution reference current compatibility information at http www hp com go ebs High Availability Cluster Options HP Serviceguard for Linux HP Serviceguard Linux x86 Server License Media including One Year 24x7 Software Support Updates 463831 B21 HP Serviceguard Linux Oracle Single Instance Database Toolkit x86 Cluster License Media including One Y...

Page 25: ...div html Worldwide HP StorageWorks Modular Smart Array 60 HP StorageWorks 60 Modular Smart Array Enclosure 418408 B21 NOTE Please see the Modular Smart Array 60 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at http h18000 www1 hp com products quickspecs 12627_div 12627_div html HP StorageWorks Modular Smart Array 70 HP Sto...

Page 26: ...1 5kVA UPS 1U JPN TW AF421A HP R3000 VA UPS 2U DTC INTL AF414A HP R3000 VA UPS 2U L5 30 NA AF422A HP R3000 VA UPS 2U L6 20 NA AF423A HP R3000 VA UPS 2U L6 20 JPN AF424A HP R3000 VA UPS 2U L5 30 JPN AF425A HP R5500 VA UPS INTL AF416A HP R5500 VA UPS NA JPN AF426A USB Options USB 1 44 MB External Diskette Drive Carbonite DC141B HP 1GB USB 2 0 Floppy Drive Key 442085 B21 HP 256MB USB 2 0 Floppy Drive...

Page 27: ...nt installed by custom systems VARs and Channels NOTE It is mandatory to use a shock pallet in order to ship racks with equipment installed NOTE Please see the Rack 10000 QuickSpecs for additional part numbers and Technical Specifications such as height width depth weight and color http h18000 www1 hp com products quickspecs 10995_div 10995_div html Worldwide NOTE For additional information regard...

Page 28: ...edia AF601A 4x1x16 IP Console Switch with Virtual Media AF602A PS 2 Virtual Media Interface Adapter 1 pack NOTE Requires PS 2 and one USB port on server AF604A Server Console Switch KVM 0 x 1 x 8 port 336044 B21 Server Console Switch KVM 0 x 2 x 16 port 336045 B21 PS 2 Interface Adapter 1 pack 262588 B21 PS 2 Interface Adapter 8 pack 262587 B21 USB Interface Adapter 1 pack 336047 B21 Serial Interf...

Page 29: ...age 3 Years Electronic U4482E Installation Start up Services Hardware Installation Electronic U4490E Installation Start Up of a ProLiant server and Microsoft or Linux O S per the Customer Description and or Data Sheet To be delivered on a scheduled basis 8am 5pm M F excl HP holidays Electronic U4491E Support Plus Onsite HW support 8am 9pm M F 4hr response and Microsoft O S SW Tech support offsite ...

Page 30: ...bank interleaved mode DIMMs must be installed in both banks with equal bank capacities Memory Slot 1A 2B 3A 4B Mode Optional 512 MB 512 MB Empty Empty Empty Single bank Standard 1 GB 1 GB Empty Empty Empty Single bank Optional 1 GB 512 MB Empty 512 MB Empty Single bank interleaved Standard 2 GB 1 GB Empty 1 GB Empty Single bank interleaved Maximum 8 GB 2 GB 2 GB 2 GB 2 GB Dual bank interleaved Fol...

Page 31: ...1 2 1 4 NOTE depending on model HP SC44Ge Host Bus Adapter HP 8 Internal Port SAS HBA with RAID HP Smart Array E200 128 BBWC Controller HP Smart Array P400 256MB Controller HP Smart Array P400 512MB BBWC Controller HP Smart Array P800 512MB BBWC Controller 3 5 SATA Hot Plug Drives Quantity Supported Position Supported Controller HP 750GB 1 5G SATA 7 2K HP 500GB 1 5G SATA 7 2K HP 250GB 1 5G SATA 7 ...

Page 32: ...or Adapter Modular Smart Array 20 Please see the Modular Smart Array 20 QuickSpecs to determine configuration requirements External Please see the Modular Smart Array 1000 QuickSpecs for the latest list of supported HBAs http www hp com go MSA20 Modular Smart Array 30 Family Up to 14 External Smart Array 6402 128 Controller Smart Array 642 Controller Modular Smart Array 60 Enclosure Up to 8 Extern...

Page 33: ... SAS Tape Drives Connecting hard drive cage and SAS tape to the same SAS Controller using split cable supplied with tape drive deactivates 1 of the hard drive bays Actual hard drive bay deactivated depends on where split cable plugs into SAS drive connector Example 3x SAS cable connector plugged into SAS drive connector 5 8 on the back of the hard drive cage would mean drive bay 8 is deactivated P...

Page 34: ...1 8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP SC44Ge Host Bus Adapter 416096 B21 HP StorageWorks Fibre Tape Automation External MSL2024 MSL4048 MSL8096 MSL6000 External Please consult the EBS connectivity matrix at http www hp com go ebs for detailed connectivity information N A HP StorageWorks D2D Backup Systems D2D110 D2D120 D2D130 External Embedded Network Controller N A QuickSpecs HP P...

Page 35: ...400 W at 100 VAC 400 W at 200 VAC Maximum Peak Power 400 W at 100 VAC 400 W at 200 VAC System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 305 m 1 8 F per every 1000 ft above sea level to a maximum of 3050 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and n...

Page 36: ... to 240 VAC Input Specifications Rated input line 90 VAC to 264VAC Frequency range 47 to 63 Hz Rated input power 115V input Rated input power 486W assume output wattage 450W 230V input Rated input power 479W assume output wattage 450W Rated input current 6 A 3 A 110 V 220 V Steady state power 420W rated BTU Rating 1710 BTU hr Ambient temperature range Operating 50 to 118 F 10 to 48 C Non operating...

Page 37: ...nctions RAID OS Support Microsoft Windows Server 2003 NOTE In order to implement integrated SATA RAID with Smart Start 7 90 on Windows 2000 2003 the use of a floppy drive is necessary Linux Red Hat SuSE UnitedLinux Embedded NC326i Dual Port Gigabit Server Adapter Network Interface 10Base T 100Base TX 1000Base TX Compatibility IEEE 802 3 10Base T IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX Data ...

Page 38: ...be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2008 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation Intel the Intel logo Xeon and Xeon Inside are trademarks of Intel Corpora...

Reviews: