System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions were
measured in accordance with ISO 7779 (ECMA 74) and declared in accordance
with ISO 9296 (ECMA 109).
Idle
LWAd
5.3 B
LpAm
38 dBA
Operating
LWAd
5.3 B
LpAm
38 dBA
NC362i Integrated Dual
Port Gigabit Server
Adapter
Network Interface
Integrated 10/100/1000BASE-T Transceiver
Combines a triple-speed IEEE 802.3TM - Compliant Media Access
Controller (MAC) with a triple-speed Ethernet transceiver.
Data Transfer Method
Compliant to x1 PCIe Specification
Controller
Intel® 82576
Network Transfer Rate
10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex) 200 Mb/s
1000Base-TX (Half and
Full-Duplex)
2000 Mb/s
Connector
RJ-45
Cable Support
Performs all the physical layer functions for 10BASE-T, 100BASE-T, and
1000BASE-T Ethernet on standard Category 5 UT
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
Technical Specifications
DA - 13248 North America — Version 53 — September 24, 2012
Page 54