background image

450GB 3G 7.2K
300GB 3G 7.2K
146GB 3G 7.2K
72GB 3G 7.2K

Up to 8

1-8

HP Smart Array E200/128 BBWC Controller
HP Smart Array P400/256MB Controller
HP Smart Array E500/256MB Controller
HP Smart Array P800/512 BBWC Controller
HP SC44Ge Host Bus Adapter
HP SC11Xe Host Bus Adapter

External Storage

External Storage

External Storage

External Storage
 

Quantity

Quantity

Quantity

Quantity

Supported

Supported

Supported

Supported

Position

Position

Position

Position

Supported

Supported

Supported

Supported

Controller

Controller

Controller

Controller

HP Storageworks MSA20
Enclosure

Up to 2 per SA

6402

Up to 4 per SA

6404

External

Smart Array 6402 Controller
Smart Array 6404 Controller

HP Storageworks MSA30
D-B Enclosure

Up to 2 per SA

6402

Up to 4 per SA

6404

External

Smart Array 6402 Controller
Smart Array 6404 Controller

HP Storageworks MSA50
Enclosure

Up to 2

External

HP Smart Array E500/256MB Controller
HP Smart Array P800 Controller
HP Smart Array P600 Controller

HP Storageworks MSA60
Enclosure

Up to 8 per SA

P800

External

HP Smart Array E500/256MB Controller
HP Smart Array P800 Controller
HP Smart Array P600 Controller

HP Storageworks MSA70
Enclosure

Up to 4 per SA

P800

External

HP Smart Array E500/256MB Controller
HP Smart Array P800 Controller
HP Smart Array P600 Controller

Tape and Disk-Based Backup

Tape and Disk-Based Backup

Tape and Disk-Based Backup

Tape and Disk-Based Backup

NOTE: 

NOTE: 

NOTE: 

NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:

http://h18000.www1.hp.com/products/quickspecs/division/10233.html

 (Worldwide)

NOTE: 

NOTE: 

NOTE: 

NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below,
please see the following:

http://h18000.www1.hp.com/products/quickspecs/division/10809.html

 (Worldwide)

NOTE: 

NOTE: 

NOTE: 

NOTE: For complete listing of tape drive offerings see:

http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html

NOTE: 

NOTE: 

NOTE: 

NOTE: SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape
drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs into SAS drive
connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would
mean drive bay 8 is deactivated.

 

Position

Position

Position

Position

Supported

Supported

Supported

Supported

Controller

Controller

Controller

Controller

Controller Part

Controller Part

Controller Part

Controller Part

Number

Number

Number

Number

QuickSpecs

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

Storage

DA - 12903   Worldwide — Version 10 — July 14, 2008

Page 25

Summary of Contents for ProLiant DL180 G5

Page 1: ...ug Power Supplies At A Glance At A Glance At A Glance At A Glance The HP ProLiant DL180 G5 is a low cost high capacity storage optimized 2 way server that delivers on a history of design excellence and 2U density for a variety of rack deployments and applications Processors Processors Processors Processors Supports up to two Quad Core Intel Xeon processors 5400 sequence with 12MB Level 2 cache Int...

Page 2: ...orm Factor 2U rack models Deployment Serviceability Deployment Serviceability Deployment Serviceability Deployment Serviceability Tooled access to all system components for easy in rack serviceability Customer Self Repair CSR HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement Warranty Warranty Warranty Wa...

Page 3: ... E5405 2 00 GHz 80W 1333MHz FSB Dual Core Intel Xeon processor E5205 1 86 GHz 65W 1066MHz FSB NOTE NOTE NOTE NOTE Available through Configure To Order only See Factory Integration Models section for more details Upgradeability Upgradeability Upgradeability Upgradeability Upgradeable to two processors Chipset Chipset Chipset Chipset Intel 5100 Chipset Cache Memory Cache Memory Cache Memory Cache Me...

Page 4: ... 0 1 NOTE NOTE NOTE NOTE A diskette drive is needed to install storage controller drivers during a Windows operating system installation from a CD NOTE NOTE NOTE NOTE A diskette drive is needed to install storage controller drivers during a Windows operating system installation from a CD Storage Storage Storage Storage Optical Drives Optical Drives Optical Drives Optical Drives DVD ROM 8x IDE ATAP...

Page 5: ...et from anywhere anytime regardless whether the server is located in the same building across town or around the globe With LO100c users can acquire complete remote control with Virtual KVM graphical hardware based remote console Users can also access the server s serial console control system power update system firmware and software as well as monitor system environmental conditions The LO100c r...

Page 6: ...mail subscription service that provides software and driver change notifications for ProLiant products Sign up at http www hp com go subscriberschoice and customize your profile to receive various new alerts as they become available on a weekly or monthly basis ROMPaq software and latest drivers The latest software drivers and firmware fully optimized and tested for your ProLiant server and option...

Page 7: ...Autoswitching Optional 750Watts Power Supply Redundant Hot Plug Autoswitching Optional 1200Watts High Efficiency Power Supply Redundant Hot Plug Autoswitching CSCI 2007 2008 Optional NOTE NOTE NOTE NOTE Climate Savers Computing Initiative 2007 2008 Compliant NOTE NOTE NOTE NOTE For additional information please see the Options section of this QuickSpecs System Fans System Fans System Fans System F...

Page 8: ...elco racks and threaded hole racks requires an additional option kit from Rack Solutions The Rack Solutions brackets can be purchased at http www racksolutions com hp Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio for Servers and Storage for Servers and Storage for Servers and Storage for Servers and Storage HP Factory Express offers configu...

Page 9: ... support offer to help you speedily deploy and maximize system uptime Recommended Service Recommended Service Recommended Service Recommended Service Simplify ProLiant solution implementation maintenance and management Support Service Support Service Support Service Support Service 3 Year 9x5 Next Business Day coverage excluding HP holidays only Deployment Service Deployment Service Deployment Ser...

Page 10: ...che 5400 sequence Memory Memory Memory Memory 1 GB 1 x 1 GB PC2 5300 DIMMs DDR2 667 with Advanced ECC capabilities Network Controller Network Controller Network Controller Network Controller One HP NC105i PCI E embedded Storage Controller Storage Controller Storage Controller Storage Controller Embedded SATA Raid Standard Hard Drive Hard Drive Hard Drive Hard Drive None ship standard up to 8 Hot P...

Page 11: ...ot Plug Fans Rack 2U 3 5 in 8 89 cm Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise noted no...

Page 12: ...D Cage requires the addition of a 4 port SAS controller that supports expanders A Smart Array Controller P400 or better is recommended NOTE NOTE NOTE NOTE The addition of a Smart Array Controller or 4 port SAS controller that supports expanders requires the addition a SAS SATA Multi lane cable 464830 B21 Step 3 Choose Additional Options for Factory Integration Step 3 Choose Additional Options for ...

Page 13: ...als Essentials Essentials Essentials NOTE NOTE NOTE NOTE Electronic licensing options are available for Insight Control suites and select ProLiant Essentials software products Please see the appropriate Insight Control and ProLiant Essentials QuickSpecs for additional information Deploy Deploy Deploy Deploy Rapid Deployment Pack Rapid Deployment Pack Rapid Deployment Pack Rapid Deployment Pack Pro...

Page 14: ... Midline MDL Drives HP 1TB 3G SATA 7 2K 3 5 MDL HDD 454146 B21 HP 750GB 3G SATA 7 2K 3 5 MDL HDD 458930 B21 HP 500GB 3G SATA 7 2K 3 5 MDL HDD 458928 B21 HP 250GB 3G SATA 7 2K 3 5 MDL HDD 458926 B21 NOTE NOTE NOTE NOTE Server BIOS update is required to support 3G SATA drives when configured with embedded SATA controller SATA Entry ETY Drives 3 5 Hot Plug SATA Entry ETY Drives 3 5 Hot Plug SATA Entr...

Page 15: ...ase see the QuickSpecs for additional information http h18000 www1 hp com products quickspecs 12566_div 12566_div html SCSI HBA Internal SAS SATA Cable NOTE NOTE NOTE NOTE If selecting more than 4 hard drives or if using SAS hard drives a Smart Array controller is required and two SAS SATA cables NOTE NOTE NOTE NOTE The addition of a Smart Array Controller requires the addition of a SAS SATA Multi...

Page 16: ...ications Communications Communications HP NC110T PCI Express Gigabit Server Adapter NOTE NOTE NOTE NOTE Does not support Windows 2000 434905 B21 HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648 B21 HP NC364T PCI Express Quad Port Gigabit Server Adapter NOTE NOTE NOTE NOTE Does not support Windows 2000 435508 B21 HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793 B21 HP ...

Page 17: ...45_div 12245_div html Worldwide HP StorageWorks HP StorageWorks HP StorageWorks HP StorageWorks Modular Smart Array 60 Modular Smart Array 60 Modular Smart Array 60 Modular Smart Array 60 HP StorageWorks 60 Modular Smart Array 418408 B21 NOTE NOTE NOTE NOTE Rack mountable 12 drive 3 5 3G SAS 1 5G SATA 2U enclosure with 3Gb s SAS host connectivity and redundant power supplies NOTE NOTE NOTE NOTE Pl...

Page 18: ...TE HP recommends combining this tape drive with the 1U SCSI Rack Mount kit A7445B for a complete rack mount solution DW064A HP StorageWorks 1U SCSI Rack mount kit with one LTO 2 Ultrium 448 SCSI Tape Drive Carbonite DW028B HP StorageWorks 1U SCSI Rack mount kit with one LTO 3 Ultrium 920 EH903A HP StorageWorks 3U SCSI Rack mount kit with one LTO 3 Ultrium 960 Carbonite Q1595B HP StorageWorks 3U SC...

Page 19: ... Disk Backup HP StorageWorks RDX160 External Removable Disk Backup System NOTE NOTE NOTE NOTE 160GB of Disk Storage AJ766A HP StorageWorks RDX320 External Removable Disk Backup System NOTE NOTE NOTE NOTE 320GB of Disk Storage AJ768A NOTE NOTE NOTE NOTE Please see the HP RDX Removable Disk Backup System QuickSpecs for additional information http h18000 www1 hp com products quickspecs 13036_div 1303...

Page 20: ...40 4GB FC Library AJ034A HP StorageWorks MSL2024 1 LTO 4 Ultrium 1760 SAS Drive Library AK378A HP StorageWorks MSL2024 1 LTO 4 Ultrium 1760 SCSI Drive Library AJ817A HP StorageWorks MSL2024 1 LTO 3 Ultrium 960 SCSI Drive Library AG115A HP StorageWorks MSL2024 1 LTO 3 Ultrium 960 4GB FC Library AG326B HP StorageWorks MSL2024 1 LTO 3 Ultrium 920 SAS Drive Library AH559A HP StorageWorks MSL2024 1 LTO...

Page 21: ...6 Server Console Switch with Virtual Media AF600A PS 2 Virtual Media Interface Adapter 1 pack NOTE NOTE NOTE NOTE Requires PS 2 and one USB port on server AF604A HP Server Console Switch KVM 0 x 1 x 8 port 336044 B21 HP Server Console Switch KVM 0 x 2 x 16 port 336045 B21 PS 2 Interface Adapter 1 pack 262588 B21 PS 2 Interface Adapter 8 pack 262587 B21 HP 1x4 Console Switch AF611A HP PS2 Server Co...

Page 22: ...e 9 Hour x 5 Day Coverage 3 Years Electronic UH270E Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service 6 Hour Call to Repair On site Service 7 Day x 24 Hour Coverage 3 Years Electronic UH273E Hardware Installation Electronic Ha...

Page 23: ...ty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Maximum 16 GB Maximum 16 GB Maximum 16 GB Maximum 16 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 4 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB Indicates the right most DIMM slots when looking from the front Following are memory options available from HP 1 ...

Page 24: ... Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 160GB 3G 7 2K Up to 8 1 8 HP Smart Array E200 128 BBWC Controller HP Smart Array P400 256MB Controller HP Smart Array E500 256MB Controller HP Smart Array P800 512 BBWC Controller HP SC44Ge Host Bus Adapter HP SC11Xe Host Bus Adapter SAS H...

Page 25: ...e and Disk Based Backup Tape and Disk Based Backup Tape and Disk Based Backup NOTE NOTE NOTE NOTE For an up to date listing of the latest O S Support details for each of the Tape Drives listed below please see the following http h18000 www1 hp com products quickspecs division 10233 html Worldwide NOTE NOTE NOTE NOTE For an up to date listing of the latest O S Support details for each of the Tape A...

Page 26: ...um 1760 SAS LTO 4 Ultrium 1840 SAS 1U Rack Mount Kit External HP SC44Ge Host Bus Adapter 416096 B21 HP StorageWorks SCSI HP StorageWorks SCSI HP StorageWorks SCSI HP StorageWorks SCSI Tape Automation Tape Automation Tape Automation Tape Automation External External External External DAT 72x10 Autoloader 1 8 G2 Tape Autoloader MSL2024 MSL4048 External HP SC11Xe Host Bus Adapter 412911 B21 HP U320e ...

Page 27: ...torageWorks RDX Removable Disk Backup Removable Disk Backup Removable Disk Backup Removable Disk Backup System System System System RDX160 RDX320 External USB 2 0 Port N A HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D Backup Systems Backup Systems Backup Systems Backup Systems D2D120 D2D130 D2D2503i D2D4004i External Embedded Network Controller N A QuickSpecs HP P...

Page 28: ... 862 Max Rated VA Max Rated VA Max Rated VA Max Rated VA Volt Amp 911 906 890 880 880 880 Efficiency Efficiency Efficiency Efficiency 84 84 5 86 87 87 87 Power Factor Power Factor Power Factor Power Factor 0 98 0 98 0 98 0 98 0 98 0 98 Leakage Current Leakage Current Leakage Current Leakage Current mA 0 43 0 50 0 90 0 96 1 00 1 04 Maximum Inrush Current Maximum Inrush Current Maximum Inrush Curren...

Page 29: ...f the next screens Power Supply Output Power Supply Output Power Supply Output Power Supply Output per power supply Rated Steady State Power Rated Steady State Power Rated Steady State Power Rated Steady State Power 750 W at 100 VAC 750 W at 200 VAC Maximum Peak Power Maximum Peak Power Maximum Peak Power Maximum Peak Power 750 W at 100 VAC 750W at 200 VAC System Inlet Temperature System Inlet Tem...

Page 30: ...nsfer Rate 10Base T Half Duplex 10 Mb s 10Base T Full Duplex 20 Mb s 100Base TX Half Duplex 100 Mb s 100Base TX Full Duplex 200 Mb s 1000Base TX Half and Full Duplex 2000 Mb s Connector Connector Connector Connector RJ 45 Cable Support Cable Support Cable Support Cable Support Performs all the physical layer functions for 10BASE T 100BASE T and 1000BASE T Ethernet on standard Category 5 UT Environ...

Page 31: ...d services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein For hard drives 1GB 1 billion bytes Actual formatted capacity is less QuickSpecs HP ProLiant DL180 Generation 5 G5 HP ProLiant DL180 Genera...

Reviews: