Removal and replacement procedures 90
System fan
The server can support up to seven system fans located on the center wall of the chassis. When the
server is installed with one processor, the system fans should be installed in the 2
nd
, 4
th
, 5
th
and 6
th
system fan locations. When the server is installed with two processors, the redundant fan functions are
supported by the system fan 1, system fan 3, and system fan 7 when installed.
Figure 86
System Fan Connections for One Processor Configuration
Figure 87
System Fan Connections for Two Processors Configuration with N+1 Redundancy Fan
Device number
Connector
System fan 1
J61 on the system board
System fan 2
J62 on the system board
System fan 3
J63 on the system board
System fan 4
J64 on the system board