Removal and replacement procedures 44
IMPORTANT:
Heatsinks for processors 1 and 2 are not interchangeable with the heatsinks for
processors 3 and 4.
9.
Install the heatsink ("
" on page
IMPORTANT:
Install all components with the same configuration that was used on the failed
system board.
10.
Install all components removed from the failed system board assembly.
11.
Install the front panel/hard drive cage assembly ("
Front panel/hard drive cage assembly
" on page
12.
Install the hard drives ("
" on page
IMPORTANT:
To avoid damage to the server blade, support the riser board when installing the
TPM board and rivet.
13.
If necessary, install the TPM module. For more information, see the
HP ProLiant BL685c G7 Server Blade
User Guide
.
14.
Install the access panel ("
" on page
After you replace the system board, you must re-enter the server blade serial number and the product ID.
1.
During the server blade startup sequence, press the
F9
key to access RBSU.
2.
Select the
Advanced Options
menu.
3.
Select
Service Options
.
4.
Select
Serial Number
. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during
the manufacturing process and should NOT be modified. This option should only
be used by qualified service personnel. This value should always match the
serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
5.
Press the
Enter
key to clear the warning.
6.
Enter the serial number and press the
Enter
key.
7.
Select
Product ID
. The following warning appears: