Component
identification
11
Activity
LED (1)
Online
LED (2)
Fault LED
(3)
Interpretation
On or
flashing
Flashing Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding or undergoing capacity expansion.
On Off Off Do not remove the drive.
The drive is being accessed, but (1) it is not configured as part of an
array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.
Flashing Flashing Flashing Do not remove the drive. Removing a drive may cause data loss
in non-fault-tolerant configurations.
Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.
Off
Off
On
The drive has failed and has been placed offline.
You may replace the drive.
Off
Off
Off
Either (1) the drive is not configured as part of an array; (2) the drive
is configured as part of an array, but it is a replacement drive that is
not being accessed or being rebuilt yet; or (3) the drive is configured
as an online spare.
If the drive is connected to an array controller, you may replace the
drive online.
Summary of Contents for PROLIANT BL45P
Page 1: ...HP ProLiant BL45p Server Blade User Guide April 2005 First Edition Part Number 378424 001 ...
Page 20: ......
Page 24: ......
Page 28: ......
Page 44: ......
Page 50: ......
Page 88: ...88 HP ProLiant BL45p Server Blade User Guide ...
Page 90: ...90 HP ProLiant BL45p Server Blade User Guide ...
Page 92: ...92 HP ProLiant BL45p Server Blade User Guide ...
Page 94: ...94 HP ProLiant BL45p Server Blade User Guide ...
Page 97: ...Troubleshooting 97 ...
Page 100: ...100 HP ProLiant BL45p Server Blade User Guide ...
Page 104: ......
Page 110: ...110 HP ProLiant BL45p Server Blade User Guide Japanese notice BSMI notice ...