Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
7.11 in x 2.03 in x 20.06 in (18.06 cm x 5.14 cm x 50.95 cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
(all hard drives and
processors installed)
14.5 lb (6.58 kg)
Minimum
(one hard drive and
processor installed)
9.4 lb (4.26 kg)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
For power specifications including Input Requirements, BTU Rating, and
Power Supply Output, please see the HP BladeSystem c-Class Enclosure
QuickSpecs located at URL:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
To review typical system power ratings use the HP BladeSystem Power Sizer
which is available via the online tool located at URL:
http://www.hp.com/go/bladesystem/powercalculator
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 85% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at URL:
QuickSpecs
HP ProLiant BL280c Generation 6 (G6) Server Blade
HP ProLiant BL280c Generation 6 (G6) Server Blade
HP ProLiant BL280c Generation 6 (G6) Server Blade
HP ProLiant BL280c Generation 6 (G6) Server Blade
Technical Specifications
DA - 13294 Worldwide — Version 22 — May 20, 2011
Page 33