background image

ProCurve Switch yl 10-GbE 2P CX4 + 2P X2 Module
(J8694A)

10-GbE module with two fixed CX4 ports and two X2 slots
for ProCurve Switch 3500yl series and ProCurve Switch
6200yl-24G-mGBIC

Ports

2 open transceiver slots
2 10-Gigabit Ethernet ports (IEEE 802.3ak
Type 10Gbase-CX4)
Duplex: full

Physical characteristics

Dimensions: 7.76 (d) x 7.52 (w) x 14.29 (h)
in. (19.7 x 19.1 x 36.3 cm)
Weight: 1.54 lb. (.7 kg)

Environment

Operating temperature: 32°F to 131°F (0°C
to 55°C)
Operating relative humidity: 15% to 95%,
non-condensing
Non-operating/Storage temperature: -40°F
to 158°F (-40°C to 70°C)
Non-operating/Storage relative humidity:
15% to 90%, non-condensing

Transceivers supported (ordered
separately)

• ProCurve 10-GbE X2-SC LR Optic
• ProCurve Switch 10-GbE X2-CX4

Transceiver

• ProCurve 10-GbE X2-SC SR Optic
• ProCurve 10-GbE X2-SC ER Optic
• ProCurve 10-GbE CX4 Media Converter

Maximum distance

CX4: 15 m (CX4 cable) or 300 m (media
converter with ribbon MMF)

Notes

Only the two fixed CX4 ports on this module
support ProCurve 10-GbE CX4 Media
Converter (J8439A).
Operating temperature is 32°F to 104°F
(0°C to 40°C) if any X2 10-GbE optic or
transceiver is inserted in any X2 slot.
One 0.5m CX4 cable is included.

zl Modules

ProCurve Switch 5400zl 24p Mini-GBIC Module
(J8706A)

24-port mini-GBIC module for 5400 series switches

Ports

24 open mini-GBIC slots

Physical characteristics

Dimensions: 10.3 (d) x 8.13 (w) x 1.75 (h)
in. (26.16 x 20.65 x 4.45 cm)
Weight: 2.01 lb. (0.91 kg)

Environment

Operating temperature: 32°F to 104°F (0°C
to 40°C)

Mini-GBICs supported (ordered
separately)

• ProCurve Gigabit-SX-LC Mini-GBIC
• ProCurve Gigabit-LX-LC Mini-GBIC
• ProCurve Gigabit-LH-LC Mini-GBIC
• ProCurve Gigabit 1000Base-T Mini-GBIC

Notes

This product requires revision "B" or later
mini-GBICs (product number ends with the
letter "B", e.g. J4858B, J4859B).
When installed in a 5400 chassis, the J8706A
module limits the operating temperature
range of the chassis to 32°F to 104°F
(0°C to 40°C).
Module available mid-2006

ProCurve Switch 3500yl-48G-PWR

12

Summary of Contents for ProCurve 3500yl-48G-PWR

Page 1: ... foundation for this switch is a purpose built programmable ProVision ASIC that allows the most demanding networking features such as QoS and security to be implemented in a scalable yet granular fashion The 3500yl 48G PWR is a part of the ProCurve 3500yl 5400zl series of switches that offer unprecedented investment protection flexibility and scalability as well as ease of deployment operation and...

Page 2: ... ports per trunk trunking across modules is supported Hot swappable modules 5400zl series permit modules mini GBICs and power supplies in a redundant power supply configuration to be added or swapped without interrupting the network Optional redundant power supply 5400zl series provides uninterrupted power and allows hot swapping of the redundant power supplies when installed Layer 2 switching Pro...

Page 3: ...pecified ports to communicate with each other TACACS eases switch management security administration by using a password authentication server Secure Shell SSHv2 encrypts all transmitted data for secure remote command line interface CLI access over IP networks Secure Sockets Layer SSL encrypts all HTTP traffic allowing secure access to the browser based management GUI in the switch Secure FTP allo...

Page 4: ...ions Friendly port names allow assignment of descriptive names to ports Dual flash images provide independent primary and secondary OS files for backup while upgrading Multiple configuration files multiple config files can be stored to flash image Port mirroring enables troubleshooting by mirroring ingress egress traffic on a port Services 3 year 4 hour onsite 13x5 coverage for hardware H4496E 3 y...

Page 5: ...C 61000 4 3 3V m EFT Burst IEC 61000 4 4 1 0 kV power line 0 5 kV signal line Surge IEC 61000 4 5 1 kV 2 kV AC Conducted IEC 61000 4 6 3V Power frequency magnetic field IEC 61000 4 8 1A m 50 or 60 Hz Voltage dips and interruptions IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods Harmonics EN61000 3 2 IEC61000 3 2 Flicker EN61000 3 3 IEC61000 3 3 Management ProCurve Manager Plus ProCu...

Page 6: ... diameter graded index low metal content multimode fiber optic complying with ITU T G 651 and ISO IEC 793 2 Type A1b or A1a respectively Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 10 km single mode or 550 m multimode Notes A mode conditioning patch cord may be needed in some multimode fiber installations ProCurve Gigabit SX LC Mi...

Page 7: ... greater Not supported on dual personality ports ProCurve Switch 10 GbE X2 CX4 Transceiver J8440B 10 Gigabit X2 transceiver that supports a CX4 connector with distance of 15 m Ports Connector CX4 Duplex full Physical characteristics Dimensions 3 54 d x 1 42 w x 0 53 h in 8 99 x 3 61 x 1 35 cm Weight 0 18 lb 0 08 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humi...

Page 8: ...ronment Operating temperature 32 F to 104 F 0 C to 40 C Operating relative humidity 15 to 95 non condensing Cabling Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 9 125 um single mode cable 2 m 10 km Notes Conditioning patch cord cables are not supported ProCurve 10 GbE X2 SC SR Optic J8436A Transceiver that supports 10G SR fiber sta...

Page 9: ...et Explorer version 5 0 or later Supported platforms HP OpenView Network Node Manager version 6 41 or 7 01 or 7 5 RADIUS server support Microsoft IAS Features Device auto discovery Topology and mapping Intuitive Explorer style interface Usable troubleshooting data and alerts Device configuration and management Customize and execute policies across groups Enhanced network security features Multiple...

Page 10: ...tion Application of policies by user identity Auto VLAN assignment Auto set quality of service by user Auto set bandwidth assignment by user Rule based access rights deployment Dynamic rights assignment based on Time Location User system Auto discovery of RADIUS servers Realms Users Additional requirements Large numbers of users may require more disk space Power supplies ProCurve Switch zl 875W Po...

Page 11: ... ProCurve Switch 3500yl series and ProCurve Switch 6200yl 24G mGBIC Ports 2 open transceiver slots 2 10 Gigabit Ethernet ports IEEE 802 3ak Type 10Gbase CX4 Duplex full Physical characteristics Dimensions 7 76 d x 7 52 w x 14 29 h in 19 7 x 19 1 x 36 3 cm Weight 1 54 lb 7 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humidity 15 to 95 non condensing Non operatin...

Page 12: ...edia converter with ribbon MMF Notes Only the two fixed CX4 ports on this module support ProCurve 10 GbE CX4 Media Converter J8439A Operating temperature is 32Â F to 104Â F 0Â C to 40Â C if any X2 10 GbE optic or transceiver is inserted in any X2 slot One 0 5m CX4 cable is included zl Modules ProCurve Switch 5400zl 24p Mini GBIC Module J8706A 24 port mini GBIC module for 5400 series switches Ports...

Page 13: ...uplex half or full Physical characteristics Dimensions 10 3 d x 8 13 w x 1 75 h in 26 16 x 20 65 x 4 45 cm Weight 2 2 lb 1 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Mini GBICs supported ordered separately ProCurve Gigabit SX LC Mini GBIC ProCurve Gigabit LX LC Mini GBIC ProCurve Gigabit LH LC Mini GBIC ProCurve Gigabit 1000Base T Mini GBIC Notes This product requires revision ...

Page 14: ...74 lb 0 79 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Transceivers supported ordered separately ProCurve 10 GbE X2 SC LR Optic ProCurve Switch 10 GbE X2 CX4 Transceiver ProCurve 10 GbE X2 SC SR Optic ProCurve 10 GbE X2 SC ER Optic Notes When installed in a 5400 chassis the J8707A module limits the operating temperature range of the chassis to 32Â F to 104Â F 0Â C to 40Â C ProCu...

Page 15: ...d services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein 06 16 06 To learn more visit www procurve com Information is subject to change without notice ...