ProCurve Gigabit 1000Base-T Mini-GBIC (J8177B)

pluggable Gigabit transceiver (RJ-45) for up to 100 m over
Cat 5 cable or better

Ports

Connector: RJ-45
Duplex: full

Physical characteristics

Dimensions: 2.56 (d) x 0.55 (w) x 0.57 (h)
in. (6.5 x 1.4 x 1.46 cm)
Weight: 0.05 lb. (0.02 kg)

Cabling

1000Base-T: Category 5 (5E or better
recommended), 100 ohm differential 4-pair
unshielded twisted pair (UTP) or shielded
twisted pair (STP) balanced, complying with
IEEE 802.3ab 1000Base-T

Maximum distance

100 m

Notes

When used in the ProCurve Switch gl 20-port
10/100/1000 Module (J4908A), the J8177B
mini-GBIC can be installed in either the upper
or lower mini-GBIC port, but will block access
to the other port.
Requires specific code version for support:
• For use with 9300m series modules,

requires code 07.08.00a or greater

• For use with 8100fl series modules,

requires CY.01.02.0050 or greater

• For use with 5300xl series modules,

requires code E.09.11 or greater (excluding
E.09.21)

• For use with 4100gl series modules,

requires code G.07.69 or greater

Not supported on dual-personality ports.

ProCurve Switch 10-GbE X2-CX4 Transceiver (J8440B)

10-Gigabit X2 transceiver that supports a CX4 connector
with distance of 15 m

Ports

Connector: CX4
Duplex: full

Physical characteristics

Dimensions: 3.54 (d) x 1.42 (w) x 0.53 (h)
in. (8.99 x 3.61 x 1.35 cm)
Weight: 0.18 lb. (0.08 kg)

Environment

Operating temperature: 32°F to 131°F (0°C
to 55°C)
Operating relative humidity: 15% to 95%,
non-condensing

Maximum distance

15 m using CX4 cables
300 m using optical media converters and
ribbon multimode fiber cable

Notes

Use CX4 10-GbE cable (0.5-15 m) or
ProCurve 10-GbE CX4 Media Converter
(J8439A)

ProCurve 10-GbE CX4 Media Converter (J8439A)

Optical media converter for CX4 (10G copper) mmf cable up
to 300 m

Ports

Duplex: full

Maximum distance

62.5 um multimode cable @ 150 MHz/km =
1-50 meters

50 um multimode cable @ 500 MHz/km =
1-100 meters
50 um multimode cable @ 2000 MHz/km =
1-300 meters

Notes

12 fiber 62.5/125 um (core/cladding)
diameter or 12 fiber 50/125 um diameter,
multimode ribbon cable with MPO/MTP to
MPO/MTP connectors
When used with the ProCurve Switch yl
10-GbE 2p CX4 + 2p X2 Module (J8694A),
only use this media converter with the fixed
CX4 ports.

ProCurve Switch 3500yl-24G-PWR

7

Summary of Contents for ProCurve 3500yl-24G-PWR

Page 1: ... foundation for this switch is a purpose built programmable ProVision ASIC that allows the most demanding networking features such as QoS and security to be implemented in a scalable yet granular fashion The 3500yl 24G PWR is a part of the ProCurve 3500yl 5400zl series of switches that offer unprecedented investment protection flexibility and scalability as well as ease of deployment operation and...

Page 2: ... ports per trunk trunking across modules is supported Hot swappable modules 5400zl series permit modules mini GBICs and power supplies in a redundant power supply configuration to be added or swapped without interrupting the network Optional redundant power supply 5400zl series provides uninterrupted power and allows hot swapping of the redundant power supplies when installed Layer 2 switching Pro...

Page 3: ...pecified ports to communicate with each other TACACS eases switch management security administration by using a password authentication server Secure Shell SSHv2 encrypts all transmitted data for secure remote command line interface CLI access over IP networks Secure Sockets Layer SSL encrypts all HTTP traffic allowing secure access to the browser based management GUI in the switch Secure FTP allo...

Page 4: ...ions Friendly port names allow assignment of descriptive names to ports Dual flash images provide independent primary and secondary OS files for backup while upgrading Multiple configuration files multiple config files can be stored to flash image Port mirroring enables troubleshooting by mirroring ingress egress traffic on a port Services 3 year 4 hour onsite 13x5 coverage for hardware U2855E 3 y...

Page 5: ...C 61000 4 3 3V m EFT Burst IEC 61000 4 4 1 0 kV power line 0 5 kV signal line Surge IEC 61000 4 5 1 kV 2 kV AC Conducted IEC 61000 4 6 3V Power frequency magnetic field IEC 61000 4 8 1A m 50 or 60 Hz Voltage dips and interruptions IEC 61000 4 11 95 reduction 0 5 period 30 reduction 25 periods Harmonics EN61000 3 2 IEC61000 3 2 Flicker EN61000 3 3 IEC61000 3 3 Management ProCurve Manager Plus ProCu...

Page 6: ... diameter graded index low metal content multimode fiber optic complying with ITU T G 651 and ISO IEC 793 2 Type A1b or A1a respectively Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 10 km single mode or 550 m multimode Notes A mode conditioning patch cord may be needed in some multimode fiber installations ProCurve Gigabit SX LC Mi...

Page 7: ... greater Not supported on dual personality ports ProCurve Switch 10 GbE X2 CX4 Transceiver J8440B 10 Gigabit X2 transceiver that supports a CX4 connector with distance of 15 m Ports Connector CX4 Duplex full Physical characteristics Dimensions 3 54 d x 1 42 w x 0 53 h in 8 99 x 3 61 x 1 35 cm Weight 0 18 lb 0 08 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humi...

Page 8: ...ronment Operating temperature 32 F to 104 F 0 C to 40 C Operating relative humidity 15 to 95 non condensing Cabling Low metal content single mode fiber optic complying with ITU T G 652 and ISO IEC 793 2 Type B1 Maximum distance 9 125 um single mode cable 2 m 10 km Notes Conditioning patch cord cables are not supported ProCurve 10 GbE X2 SC SR Optic J8436A Transceiver that supports 10G SR fiber sta...

Page 9: ...et Explorer version 5 0 or later Supported platforms HP OpenView Network Node Manager version 6 41 or 7 01 or 7 5 RADIUS server support Microsoft IAS Features Device auto discovery Topology and mapping Intuitive Explorer style interface Usable troubleshooting data and alerts Device configuration and management Customize and execute policies across groups Enhanced network security features Multiple...

Page 10: ...tion Application of policies by user identity Auto VLAN assignment Auto set quality of service by user Auto set bandwidth assignment by user Rule based access rights deployment Dynamic rights assignment based on Time Location User system Auto discovery of RADIUS servers Realms Users Additional requirements Large numbers of users may require more disk space Power supplies ProCurve Switch zl 875W Po...

Page 11: ... ProCurve Switch 3500yl series and ProCurve Switch 6200yl 24G mGBIC Ports 2 open transceiver slots 2 10 Gigabit Ethernet ports IEEE 802 3ak Type 10Gbase CX4 Duplex full Physical characteristics Dimensions 7 76 d x 7 52 w x 14 29 h in 19 7 x 19 1 x 36 3 cm Weight 1 54 lb 7 kg Environment Operating temperature 32 F to 131 F 0 C to 55 C Operating relative humidity 15 to 95 non condensing Non operatin...

Page 12: ...edia converter with ribbon MMF Notes Only the two fixed CX4 ports on this module support ProCurve 10 GbE CX4 Media Converter J8439A Operating temperature is 32Â F to 104Â F 0Â C to 40Â C if any X2 10 GbE optic or transceiver is inserted in any X2 slot One 0 5m CX4 cable is included zl Modules ProCurve Switch 5400zl 24p Mini GBIC Module J8706A 24 port mini GBIC module for 5400 series switches Ports...

Page 13: ...uplex half or full Physical characteristics Dimensions 10 3 d x 8 13 w x 1 75 h in 26 16 x 20 65 x 4 45 cm Weight 2 2 lb 1 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Mini GBICs supported ordered separately ProCurve Gigabit SX LC Mini GBIC ProCurve Gigabit LX LC Mini GBIC ProCurve Gigabit LH LC Mini GBIC ProCurve Gigabit 1000Base T Mini GBIC Notes This product requires revision ...

Page 14: ...74 lb 0 79 kg Environment Operating temperature 32 F to 104 F 0 C to 40 C Transceivers supported ordered separately ProCurve 10 GbE X2 SC LR Optic ProCurve Switch 10 GbE X2 CX4 Transceiver ProCurve 10 GbE X2 SC SR Optic ProCurve 10 GbE X2 SC ER Optic Notes When installed in a 5400 chassis the J8707A module limits the operating temperature range of the chassis to 32Â F to 104Â F 0Â C to 40Â C ProCu...

Page 15: ...d services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein 06 16 06 To learn more visit www procurve com Information is subject to change without notice ...

Reviews: