7-18
ProCurve Stack Management
Configuring Stack Management
•
To change
Auto Join
or
Transmission Interval
, use
[Tab]
to select the
desired parameter, and:
–
To change
Auto Join
, use the Space bar.
–
To change
Transmission Interval
, type in the new value in the
range of 1 to 300 seconds.
Note:
All switches in the stack must be set to the same transmis-
sion interval to help ensure proper stacking operation. ProCurve
recommends that you leave this parameter set to the default 60
seconds.
Then go to step 5.
5.
Press
[Enter]
to return the cursor to the
Actions
line.
6.
Press
[S]
(for
Save
) to save your configuration changes and return to the
Stacking menu.
Using the Commander To Manage The Stack
The Commander normally operates as your stack manager and point of entry
into other switches in the stack. This typically includes:
■
Adding new stack members
■
Moving members between stacks
■
Removing members from a stack
■
Accessing stack members for individual configuration changes and traffic
monitoring
The Commander also imposes its passwords on all stack members and pro-
vides SNMP community membership to the stack. (See “SNMP Community
Operation in a Stack” on page 7-45.)
Summary of Contents for ProCurve 2810-24G
Page 1: ...Advanced Traffic Management Guide 2810 www procurve com ProCurve Series 2810 Switches N 11 XX ...
Page 2: ......
Page 3: ...ProCurve Series 2810 Switches Advanced Traffic Management Guide July 2007 ...
Page 11: ...ix Web Viewing and Configuring Stacking 7 47 Status Messages 7 48 Index ...
Page 12: ...x ...
Page 76: ...3 18 GVRP Introduction ...
Page 271: ......