background image

HP ProCurve Switch 2600 Series

8

Safety

CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950;
NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

CSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950;
NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

Immunity

Generic

EN 55024, CISPR 24

EN 55024, CISPR 24

EN

EN 55024, CISPR 24

EN 55024, CISPR 24

ESD

IEC 61000-4-2; 4 kV CD, 8 kV AD

IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated

IEC 61000-4-3; 3 V/m

IEC 61000-4-3; 3 V/m

EFT/Burst

IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

Surge

IEC 61000-4-5; 1 kV/2 kV AC

IEC 61000-4-5; 1 kV/2 kV AC

Conducted

IEC 61000-4-6; 3 V

IEC 61000-4-6; 3 V

Power frequency magnetic field

IEC 61000-4-8; 1 A/m, 50 or 60 Hz

IEC 61000-4-8; 1 A/m, 50 or 60 Hz

Voltage dips and interruptions

IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25
periods

IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25
periods

Harmonics

EN 61000-3-2, IEC 61000-3-2

EN 61000-3-2, IEC 61000-3-2

Flicker

EN 61000-3-3, IEC 61000-3-3

EN 61000-3-3, IEC 61000-3-3

Management

HP ProCurve Manager Plus; HP ProCurve Manager (included);
command-line interface; Web browser; configuration menu;
out-of-band management (serial RS-232C)

HP ProCurve Manager Plus; HP ProCurve Manager (included);
command-line interface; Web browser; configuration menu;
out-of-band management (serial RS-232C)

Services

3-year, 4-hour onsite, 13x5 coverage for hardware (U2855E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U2856E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software
phone support (U6304E)
3-year, 24x7 SW phone support, software updates (UE262E)
Installation with minimum configuration, system-based pricing
(U4826E)
Installation with HP-provided configuration, system-based pricing
(U4830E)

Refer to the HP Web site at 

www.procurve.com/services

 for details

on the service-level descriptions and product numbers. For details
about services and response times in your area, please contact your
local HP sales office.

3-year, 4-hour onsite, 13x5 coverage for hardware (UD537E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UD538E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software
phone support (UD539E)
3-year, 24x7 SW phone support, software updates (UF793E)
Installation with minimum configuration, system-based pricing
(U4826E)
Installation with HP-provided configuration, system-based pricing
(U4830E)

Refer to the HP Web site at 

www.procurve.com/services

 for details

on the service-level descriptions and product numbers. For details
about services and response times in your area, please contact your
local HP sales office.

Standards and protocols

Device management

HTML and telnet management

General protocols

IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1w Rapid Reconfiguration of
Spanning Tree
IEEE 802.3ad Link Aggregation
Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 951 BOOTP
RFC 1542 BOOTP Extensions

RFC 2030 Simple Network Time
Protocol (SNTP) v4
RFC 3046 DHCP Relay Agent
Information Option

IP multicast

RFC 2236 IGMPv2

MIBs

RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q
Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2863 The Interfaces Group MIB

Network management

IEEE 802.1AB Link Layer Discovery
Protocol (LLDP)
RFC 2819 Four groups of RMON: 1
(statistics), 2 (history), 3 (alarm) and 9
(events)
RFC 3164 BSD syslog Protocol
ANSI/TIA-1057 LLDP Media Endpoint
Discovery (LLDP-MED)
SNMPv1/v2c/v3

Security

IEEE 802.1X Port Based Network
Access Control
RFC 1492
RFC 2138 RADIUS Authentication
RFC 2866 RADIUS Accounting
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

Summary of Contents for ProCurve 2600

Page 1: ...2600 series is a collection of low cost stackable multi layer managed switches with 48 24 or 8 auto sensing 10 100 ports and dual personality ports for 10 100 1000 or mini GBIC connectivity The ProCurve Switch 2650 PWR 2626 PWR and 2600 8 PWR are IEEE 802 3af compliant for Power over Ethernet and provide up to 15 4 W per port A redundant external power supply is also available as an accessory ...

Page 2: ...r specified by the administrator MAC address lockout prevents configured particular MAC addresses from connecting to the network Dynamic IP lockdown works with DHCP protection to block traffic from unauthorized hosts preventing IP source address spoofing Dynamic ARP protection blocks ARP broadcasts from unauthorized hosts preventing eavesdropping or theft of network data Multiple user authenticati...

Page 3: ...gnment of descriptive names to ports Auto MDIX automatically adjusts for straight through or crossover cables on all 10 100 1000 ports Dual flash images provides independent primary and secondary operating system files for backup while upgrading Stacking capability single IP address management for a virtual stack of up to 16 switches including the HP ProCurve Switch 2500 Series 2510 Series 2600 Se...

Page 4: ... 15 lb 4 15 kg Fully loaded Memory and processor Processor Motorola PowerPC MPC8245 266 MHz 8 MB flash 32 MB SDRAM Motorola PowerPC MPC8245 266 MHz 8 MB flash 32 MB SDRAM Motorola PowerPC MPC8245 266 MHz 8 MB flash 32 MB SDRAM Mounting Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in telco rack or equ...

Page 5: ... 3 Management HP ProCurve Manager Plus HP ProCurve Manager included command line interface Web browser configuration menu out of band management serial RS 232C HP ProCurve Manager Plus HP ProCurve Manager included command line interface Web browser configuration menu out of band management serial RS 232C HP ProCurve Manager Plus HP ProCurve Manager included command line interface Web browser confi...

Page 6: ...HCP Relay Agent Information Option IP multicast RFC 2236 IGMPv2 MIBs RFC 1213 MIB II RFC 1493 Bridge MIB RFC 2021 RMONv2 MIB RFC 2096 IP Forwarding Table MIB RFC 2613 SMON MIB RFC 2618 RADIUS Client MIB RFC 2665 Ethernet Like MIB RFC 2668 802 3 MAU MIB RFC 2674 802 1p and IEEE 802 1Q Bridge MIB RFC 2737 Entity MIB Version 2 RFC 2863 The Interfaces Group MIB Network management IEEE 802 1AB Link Lay...

Page 7: ... in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Mounts in an EIA standard 19 in telco rack or equipment cabinet hardware included horizontal surface mounting only Performance Latency 12 µs LIFO 12 µs LIFO Throughput up to 6 6 million pps up to 6 6 million pps Routing Switching capacity 9 6 Gbps 9 6 Gbps MAC address table size 8000 entrie...

Page 8: ...es for details on the service level descriptions and product numbers For details about services and response times in your area please contact your local HP sales office 3 year 4 hour onsite 13x5 coverage for hardware UD537E 3 year 4 hour onsite 24x7 coverage for hardware UD538E 3 year 4 hour onsite 24x7 coverage for hardware 24x7 software phone support UD539E 3 year 24x7 SW phone support software...

Page 9: ...gabit Uplink J8762A NEW HP ProCurve 1000 BX D SFP LC Mini GBIC J9142B NEW HP ProCurve 1000 BX U SFP LC Mini GBIC J9143B For more information To learn more about HP ProCurve Networking please visit ProCurve com 2008 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the expres...

Reviews: