Failed transceiver
When a transceiver (or Gigabit Interface Converter (GBIC)) fails, the Disk Enclosure Properties
window displays the following information:
•
On the Power tab, the operational state displays
Good
.
•
On the Cooling tab, the status of the sensors displays
OK
.
•
On the I/O-Comm tab, the operational state of the I/O modules displays
Bad
or
Not
Installed
.
See the user guide for your controller to view the event log entries for this entity.
Failed I/O module
When an I/O module fails, the Disk Enclosure Properties window displays the following information:
•
On the Power tab, the operational state displays
Good
.
•
On the Cooling tab, the status of the sensors displays
OK
.
•
On the I/O-Comm tab, the operational state of the I/O modules displays
Not Installed
or
Failed
.
See the user guide for your controller to view the event log entries for this entity.
Failed blower power supply
When a blower power supply fails, the Disk Enclosure Properties window displays the following
information:
•
On the Power tab, the operational state of a power supply displays
Unknown
.
•
On the Cooling tab, the operational state of a blower displays
Unknown
and the status of the
power supply temperature sensor displays
Not Available
.
See the user guide for your controller to view the event log entries for this entity.
Troubleshooting access to array-based HP P6000 Command View
Problem
The logon to array-based HP P6000 Command View indicates
Access Denied
.
Explanation / Resolution
The HP P6000 Command View client filter in the HP P6000 Control Panel is enabled and access
has been denied.
66
Troubleshooting HP P6000 Command View