Solution
Closed fixes summary
Fixed in HP Network Advisor 11.1.0.
In the Client, IFL/ISL connections are not being displayed correctly in
the topology view when multiple circuits are added with different GigE
ports for a tunnel.
Fixed in HP Network Advisor 11.1.0.
For zoning, sorting of ports is not accurate in the Hex display mode
for the user port number.
Fixed in HP Network Advisor 11.1.0.
In the Client, the latest topology changes are not reflected; the yellow
dotted line is not shown when the tunnel is deleted.
Fixed in HP Network Advisor 11.1.0.
In the Device Tree, on selecting an E_Port on switch1, after 1 minute
focus changes to the same port under switch-2, and is misleading to
the user.
Fixed in HP Network Advisor 11.1.0.
When a user attempts to delete a logical switch the operation may fail
with the error message
internal server error
.
Workaround prior to upgrade:
Close
and reopen the circuit dialog on
different circuits to perform the edit
operation.
Fixed in HP Network Advisor 11.1.0.
A user is unable to edit the commit rate of a second circuit after the
first circuit has been modified without closing and reopening the FCIP
Tunnel dialog box.
Fixed in HP Network Advisor 11.1.0.
In the Client, the Logical Switch Sequence Number is displayed incor-
rectly in the Switch Properties Dialog.
Fixed in HP Network Advisor 11.1.0.
In Port Fencing, Switch-level Alert was missing when a port is fenced
for Link reset violation type.
Workaround prior to upgrade:
Change commit rates on both the
local and remote ends separately
through the CLI if there are different
VLAN tags at both ends.
Fixed in HP Network Advisor 11.1.0.
FCIP Circuits do not come up and stay in an 'In progress' state after
changing the commit rate.
Workaround prior to upgrade:
Hit the
refresh button in the target dialog to
see the hosts configured.
Fixed in HP Network Advisor 11.1.0.
At times hosts are not displayed and a user will not be able to view
the LUNs configured for a container.
Workaround prior to upgrade:
Add
syslog registration via the CLI.
Fixed in HP Network Advisor 11.1.0.
Syslog registration fails for HP StorageWorks 4/32B SAN Switches
with a McDATA OUI 08:00:88
Fixed in HP Network Advisor 11.1.0.
Encryption HAC Failover status not displayed.
Fixed in HP Network Advisor 11.1.0.
Decommissioning a LUN in an Encryption Group (EG) that is configured
with TKLM returns an error message that is invisible to the user.
Workaround prior to upgrade:
Configure valid IP addresses for all
switches in the fabric.
Fixed in HP Network Advisor 11.1.0.
Unable to discover fabric in DCFM if IP address of any member switch
is 0.0.0.0.
HP Network Advisor B-series Enterprise, Professional Plus, and Professional 11.1.1 Release
Notes
21