MSM323-R Integrated Services Access Point Quickstart 

4

HP ProCurve Networking

13.

Carefully pull the cable slack back through the quick-disconnect assembly until the RJ-
45 Plug (G) is almost touching the Body (F). Adjust the cable position so that the RJ-45 
Plug (G) fits precisely into the RJ-45 cutout in the Body (F), and press down the plastic 
tab so the plug fits correctly.

14.

Tighten the threads between Sealing Nut (A) and Clamp Ring (C) 

by hand

, until the cable 

is firmly anchored. 

Do not over tighten. Do not tighten with tools.

Install the MSM323-R

1.

Mount the MSM323-R on a wall or pole using the supplied brackets so that the antennas 
are pointing up. Local electrical and building codes will dictate many installation 
aspects.

2.

(Refer to photo below: “Grounded body (via grounding lug).”) Attach the supplied 
grounding lug (through the bracket) to one of the lower screw holes on the MSM323-R 
body, and attach a grounding wire with the set screw.

3.

(Refer to the photo on the left side of page 1.) Manually screw on antenna surge 
suppressors to the antenna connectors on top of the MSM323-R. Position the gas tube 
covers so that they can be removed for future tube replacement.

4.

(Refer to photo below: “Grounded surge suppressor.”) Attach a grounding wire to at 
least one of the antenna surge suppressors. For the model shown, remove the crimp 
connector, crimp it to the wire, and then screw the crimp connector back onto the surge 
suppressor.

5.

Create a drip loop in the Ethernet cable below the MSM323-R. A drip loop provides 
additional protection against water running down the Ethernet cable and into the 
connector. Form the loop as shown here. Make sure that the distance between the loop 
start and end points is at least 6 inches (15 cm), and that the cable hangs down at least 
10 inches (25 cm).

6.

(Refer to illustration “Weatherproof connector parts” on previous page.) Mate the RJ-45 
Plug (G) with the socket on the MSM323-R, hold it firmly in place, and tighten the Screw 
Nut (E)

 by hand. Do not over tighten. Do not tighten with tools.

7.

Install an Ethernet surge suppressor as close as possible to the MSM323-R, ideally 
within two feet (.6 meters). This helps reduce the effects of any charge carried by the 
cable to the MSM323-R. Install this Ethernet surge suppressor between the MSM323-R 
and the PoE power source. 

The Ethernet cable will typically need to be cut and have the cable end coming from the 
PoE injector connected to the Ethernet surge suppressor input (Line) and have the cable 
end coming from the MSM323-R connected to the Ethernet surge suppressor output 
(Equipment). Follow the instructions included with the Ethernet surge suppressor. 
Include a drip loop for both the input and output cables. Connect a grounding wire to the 
Ethernet surge suppressor.

Powering the MSM323-R

The MSM323-R can be powered by:

A PoE-enabled switch. A number of PoE-enabled switches are available from HP 
ProCurve.

HP ProCurve PoE 1-Port Power Injector (J9407A). 

Initial software configuration

This section walks you through the steps needed to configure the MSM323-R

 

and establish a 

connection through the MSM323-R to the Internet.

The MSM323-R is managed via its web-based management tool using at least Microsoft 
Internet Explorer 7.0 or Mozilla Firefox 2.0.

Note:

Do not power on the MSM323-R until directed.

Surge suppressor not exactly as shown

Summary of Contents for MSM323-R

Page 1: ...ess VIEW Certification Program VIEW Certified MSM323 R Integrated Services Access Point Quickstart This Quickstart introduces the MSM323 R US J9342A WW J9345A Integrated Services Access Point formerly the MSC 3300R MultiService Controller and shows you how to get started using it After following the directions in this Quickstart see the MSC 3000 Series Admin Guide available at www procurve com cus...

Page 2: ...lure to do so may result in personal injury fire equipment damage or a voided warranty The HP ProCurve hardware warranty provides no protection against damage caused by static discharge or a lightning strike Cabling You must use the appropriate cables and where applicable surge protection for your given region For compliance with EN55022 Class B emissions requirements use shielded Ethernet cables ...

Page 3: ...t parts kit 2 If your Cat5 Ethernet cable already has an RJ 45 connector on the end that will connect to the HP ProCurve equipment remove the RJ 45 connector by cutting the cable at least half an inch 1 2 cm before the RJ 45 connector Be sure to make a clean cut with a pair of sharp angle cutters The complete cut through both the cable sheath and all wires must occur in a single cutting motion 3 H...

Page 4: ...own the Ethernet cable and into the connector Form the loop as shown here Make sure that the distance between the loop start and end points is at least 6 inches 15 cm and that the cable hangs down at least 10 inches 25 cm 6 Refer to illustration Weatherproof connector parts on previous page Mate the RJ 45 Plug G with the socket on the MSM323 R hold it firmly in place and tighten the Screw Nut E by...

Page 5: ...mpt appears If it does select the country in which this product will be used and select Save WARNING The country must be set accurately to the country in which the MSM323 R will operate 7 At the password prompt it is recommended that you change the password Specify the new password and select Save Note Passwords must contain at least six characters including four different characters Management to...

Page 6: ...ned in step E 2 above 2 Connect your computer to the same network as the MSM323 R 3 Look in the DHCP server log for the Ethernet Base MAC address shown on the MSM323 R label and take note of the corresponding IP address 4 Relaunch the MSM323 R management tool this time using https IP address discovered in previous step to continue configuring the MSM323 R Assigning an IP address The Internet port ...

Reviews: