Hardware options installation 40
CAUTION:
To prevent possible server malfunction, do not mix processors of different speeds or cache
sizes. Refer to the label on the processor heatsink for a description of the processor.
IMPORTANT:
Populate the processors in the following order: 1, 2, 4, 3.
IMPORTANT:
If upgrading processor speed or adding additional processors, update the system ROM
before installing the processor.
IMPORTANT:
Processor socket 1 and PPM slot 1 must be populated at all times or the server does not
function properly.
IMPORTANT:
Always install a PPM when you install a processor. The system fails to boot if the PPM is
missing.
IMPORTANT:
To ensure proper cooling, be sure the processor baffle is installed at all times.
To install a processor:
1.
Power down the server (on page
27
).
2.
Extend the server from the rack, if applicable ("
Extending the server from the rack
" on page
27
).
3.
Remove the access panel ("
Access panel
" on page
31
).
4.
Remove the processor air baffle.