Chapter 5
Troubleshooting
58
2. Power down the HP NetServer.
3. Disconnect the power cords and cables and, if necessary, label each one to support re-
assembly.
CAUTION
The power supplies will continue to provide standby current to the NetServer until
the power is disconnected.
4. For both rack-mounted and pedestal models, remove the covers to gain access to the system
board assembly.
NOTE
In the LH 6000r, this assembly is under the right cover; in the LH 6000, it is under
the top cover.
While you can clear the system configuration in the rack or in the pedestal, it is recommended that you
remove the system board assembly to perform configuration changes
CPU Speed
CPU Speed
CPU Speed
Clear Config
Clear Password
Not Used
1
2
3
4
5
6
7
8
O
N
Switches 1 and 4 of
dual in-line switch,
S1, shown in the ON
position.
System Board Assembly and Configuration Switch
5. Move the configuration switch, switch 5 on the system board, to the "ON = CLEAR CONFIG"
position.