background image

ProCurve Switch 2124

Specifications

Ports

24 10/100 ports (IEEE 802.3
Type 10Base-T, IEEE 802.3u
Type 100Base-TX)
1 open transceiver slots

Physical characteristics

Dimensions
8.0(d) x 17.4(w) x 1.8(h) in.
(20.32 x 44.2 x 4.57 cm) (1U
height)
Weight
8.25 lb. (3.74 kg)

Memory and processor

Packet buffer size: 768 KB

Mounting

Mounts in a standard 19 in.
rack (hardware included)

Performance

Latency:

- <8.5 µs (LIFO)

Switching capacity: 2.6 Gbps
Routing table size: 4,096
entries

Environment

Operating

- Temperature: 32°F to 131°F

(0°C to 55°C)

- Relative humidity: 15% to

95% @ 104°F (40°C),
non-condensing

Non-operating/Storage

- Temperature: -40°F to

158°F (-40°C to 70°C)

- Relative humidity: 90% to

90% @ 149°F (65°C),
non-condensing

Shock: HP759, HP760 (similar
to EN 60068 IEC 68)
Acoustic: DIN 27779 per ISO
7779 42 dB

Electrical characteristics

Max heat dissipation: 341
BTU/hr
Voltage: 100-240 VAC
Current: 1.0 A
Power consumption: 100 W
Frequency: 50/60 Hz

Safety

cUL (CSA 950); EN 60950/IEC
60950; NOM-019-SCFI-1994;
UL 1950 3rd edition

Emissions

FCC Class A;
EN55022/CISPR-22 Class A;
VCCI Class A

Immunity

Generic: EN55024, CISPR 24
EN: EN55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD,
8 kV AD
Radiated: IEC 61000-4-3;
3V/m
EFT/Burst: IEC 61000-4-4; 1.0
kV (power line), 0.5 kV (signal
line)
Surge: IEC 61000-4-5; 1 kV/2
kV AC
Conducted: IEC 61000-4-6; 3V

Power frequency magnetic
field: IEC 61000-4-8; 1A/m, 50
or 60 Hz
Voltage dips and interruptions:
IEC 61000-4-11; >95%
reduction, 0.5 period, 30%
reduction, 25 periods
Harmonics: EN61000-3-2,
IEC61000-3-2
Flicker: EN61000-3-3,
IEC61000-3-3

Standards and protocols

IEEE 802.3x Flow Control

3

Summary of Contents for J4868A

Page 1: ...Switch 2124 is a low cost unmanaged 24 port switch with 10 100 auto sensing per port and 1 open transceiver slot for a 100Base FX uplink The ProCurve Switch 2124 offers ProCurve Auto MDIX on all 10 100 ports ProCurve Switch 2124 J4868A ...

Page 2: ...and ease of use Ease of use Unmanaged provides plug and play simplicity Use on desktop or rack mounted quiet operation enables flexible use 1U form factor the industry s most frequently requested size Industry leading warranty Lifetime warranty for as long as you own the product with next business day advance replacement available in most countries Services 3 year 4 hour onsite 13x5 coverage for h...

Page 3: ...densing Shock HP759 HP760 similar to EN 60068 IEC 68 Acoustic DIN 27779 per ISO 7779 42 dB Electrical characteristics Max heat dissipation 341 BTU hr Voltage 100 240 VAC Current 1 0 A Power consumption 100 W Frequency 50 60 Hz Safety cUL CSA 950 EN 60950 IEC 60950 NOM 019 SCFI 1994 UL 1950 3rd edition Emissions FCC Class A EN55022 CISPR 22 Class A VCCI Class A Immunity Generic EN55024 CISPR 24 EN ...

Page 4: ...w x 0 95 h in 9 65 x 5 21 x 2 41 cm Weight 0 09 lb 0 04 kg Cabling 62 5 125 µm or 50 125 µm core cladding diameter graded index low metal content multimode fiber optic complying with ITU T G 651 and ISO IEC 793 2 Type A1b or A1a respectively Maximum distance 2 km full duplex or 412 m half duplex Notes Full duplex only when installed in unmanaged switches and ProCurve Switch 2500 series ProCurve Sw...

Page 5: ...ts and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein To learn more visit www procurve com Information is subject to change without notice ...

Reviews: