EL-MF877-00
Page 2
Template Revision A
2.0 Tools Required
List the type and size of the tools that would typically be used to disassemble the product to a point where components
and materials requiring selective treatment can be removed.
Tool Description
Tool Size (if
applicable)
Torx screwdriver
T5, T8 & T10
3.0 Product Disassembly Process
3.1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment:
3.1.1
Mechanism disassembly: remove the front panel (clip fit – two clips top, two bottom), and remove the lid and the
base. You will need to cut the 4 x tamper-proof tapes, top and bottom to clip off the lid and the base.
3.1.2
Remove the main PCA. Disconnect all FFC / FPC connectors and 1 x cable connector The main PCA is > 10
square cm’s. See image 1. When the PCA is removed, remove the PCA shield - located underneath the main PCA
and secured by 2 x T-10 screws – see image 1.
3.1.3
Remove the CMWP PCA. Slide the cartridge assembly 2 cm back into the mechanism. Remove 5 x T-5 screws
securing the PCA and remove from the mechanism. PCA is > 10 square cm’s – see image 2.
3.1.4
Remove the 2 x reel motor PCAs. Remove the tape reel. 3 x T-10 screws and cut the tape. Once removed,
remove 3 x T-8 screws securing the front reel motor PCA and 3 x T-8 screws securing the rear reel motor PCA.
Both reel motor PCAs are > 10 square cm’s. See image 3.
3.2 Optional Graphic. If the disassembly process is complex, insert a graphic illustration below to identify the items
contained in the product that require selective treatment (with descriptions and arrows identifying locations).
1)
Main PCA.
Above: PCA shield
2)
CMWP PCA.
5 x T-5 screws
PCA > 10 square cm’s
T-10
CMWP PCA > 10 square cm
T-10