D–2
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Event, Error and Warning Messages
22
Error reading BMC token on upload to
NVM
—
23
Error reading BMC first boot token
—
24
Primary FIT failed
Reflash firmware
25
Secondary FIT failed
Reflash firmware
26
PAL_A warning. One copy of PAL is bad
Reflash firmware
27
PAL_B warning. Not compatible with at
least one CPU
Update firmware
28
Memory errors detected and PDT is
disabled
Reseat DIMMs, if error persists
replace bad DIMMs
30
Memory required reinterleave to get a
good page 0
—
31
One or more ranks have chipspare
disabled
—
33
One or more memory ranks are
mismatched and deallocated
Fix memory loading order
(page 2-25)
34
Memory deallocated because of a loading
error
Fix memory loading order
(page 2-25)
35
Memory is not loaded recommended
loading order
Fix memory loading order
(page 2-25)
36
The PDT is full
Clear with
pdt
clear
command in
EFI shell
37
At least one (1) CPU has bad fixed core
ratio
—
38
All CPUs were slated for compatibility
deconfig
—
39
Incompatible CPUs detected
Call support center
40
CPUs installed with mixed cache sizes
This will always cause a stopboot
41
CPUs installed with mixed steppings
—
42
All CPUs are over clocked
—
43
At least one (1) CPU is over clocked
—
44
Monarch changed to lowest stepping CPU Only seen once after monarch is
set to lowest stepping
46
CPUs loaded in wrong order
—
48
SAL NVM cleared
Information only, no action
required
Error Number
Error/Warning Message
Solution