Maintenance Switch
The HPE ProCurve maintenance switch provides the communication between the NS2300 system
through the VIO enclosures, CLIMs, the optional UPS, and the system console running or
accessing OSM software.
The NS2300 system requires multiple connections to the maintenance switch. For more
information, refer your service provider to the
NonStop NS2100 and NS2300 System Hardware
Installation Manual
or to the
for the system.
System Console
A system console is a Windows Server purchased from Hewlett Packard Enterprise that runs
maintenance and diagnostic software for NS2300 systems. When supplied with a new NS2300
system, system consoles have factory-installed Hewlett Packard Enterprise and third-party
software for managing the system. You can install software upgrades from the NonStop System
Console Installer DVD.
UPS and ERM (Optional)
A rack-mounted uninterruptible power supply (UPS) is optional but recommended to provide
power during power failures when a site UPS is not available.
NOTE:
For information on using OSM to manage: a site UPS, AC power monitoring, or for
power fail support, see the
OSM Configuration Guide
.
HPE supports these rack-mounted UPS modules which support up to two HPE ERMs per UPS;
no mixing of UPS and ERM types.
UPS Manuals
Supported UPS
HPE UPS R5000 User Guide
Single-phase R5000
HPE UPS Network Module User Guide
HPE 3 Phase UPS User Guide
Three-phase R12000/3
HPE UPS Management Module User Guide
More information
Power Specifications
UPS and ERM Checklist
UPS and ERM Checklist
Verify:
√
UPS’s and ERMs are in the lowest portion of the system to avoid tipping and stability issues.
No more than two HPE ERMs are used per UPS; no mixing of UPS or ERM types.
The manufacturing default setting ride-through time for the optional HPE-supported UPS has been changed
to an appropriate value for the system. Service providers can refer to the
NonStop NS2100 and NS2300
Hardware Installation Manual
for these instructions
Your UPS configuration is supported. See
“UPS and Data Center Power Configurations” (page 64)
18
NS2300 System Overview
Summary of Contents for Integrity NonStop i NS2300
Page 5: ...Ukraine RoHS material content declaration 79 Index 80 Contents 5 ...
Page 9: ...Figure 1 Example NS2300 System Configuration 42U 9 ...
Page 31: ...Figure 3 Intelligent PDU Connections Without UPS Power Distribution for NS2300 Systems 31 ...
Page 39: ...Figure 10 Example of Top AC Power Feed Without UPS Power Distribution for NS2300 Systems 39 ...