HSG80 Array Controller V8.7 Maintenance and Service Guide
4–3
Replacement Procedures for Model 2200 Enclosure Elements
2. Mount the logical units on the host.
3. If using a Windows NT or Windows 2000 platform, restart the server.
Replacement Procedures for Controller and Cache
Modules in a Single-Controller Configuration
This section shows how to replace modules in a single-controller configuration (see
Figure 4–2), to include: replacing both the controller and cache module, replacing
only the controller, and replacing only the cache module. To upgrade a
single-controller configuration to a dual-redundant controller configuration, see
Chapter 5.
Figure 4–2: Single-controller configuration in a Model 2200 enclosure
CAUTION: In a single-controller configuration, always shut down the subsystem
before removing or replacing any modules. Otherwise, data loss might occur.
For fiber optic cables without extender clips, thin needle-nose pliers must be used to
remove the cable from the controller without potentially damaging the cable (see
Figure 4–3).