To replace the component, reverse the removal procedure.
Powering down the server
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.
Prerequisites
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data
and programs.
Procedure
1. Remove the bezel.
2. To power down the server, use one of the following methods.
• Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.
• Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS. If an
application stops responding, you can use this method to force a shutdown.
• Use a virtual power button selection through iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby
mode.
3. Verify that the server is in standby mode by observing that the system power LED is amber.
Extending the server from the rack
To perform this procedure, you will need a T-25 screwdriver.
Removal and replacement procedures
31
Summary of Contents for HPE ProLiant DL325
Page 24: ...Customer self repair 24 ...
Page 25: ...Customer self repair 25 ...
Page 26: ...Customer self repair 26 ...
Page 61: ... SFF a Remove the optical drive cage b Remove the blank Removal and replacement procedures 61 ...
Page 136: ... Slot 2 Slot 3 Cabling 136 ...
Page 139: ... Slot 2 Slot 3 Cabling 139 ...
Page 145: ... SFF Cable routing Power supply Non hot plug power supply Cabling 145 ...
Page 149: ...Cable routing Serial port Cabling 149 ...
Page 152: ... Slot 2 Slot 3 Cabling 152 ...