![HP HP 8924C Application Manual Download Page 40](http://html.mh-extra.com/html/hp/hp-8924c/hp-8924c_application-manual_166201040.webp)
40
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcal.fb
Chapter 1, Calibrating the Test Set
Zeroing Average Power Measurements
4. Zero the Average Power measurement.
HP-IB Syntax
"MEAS:CDM:AVGP:ZERO" ! zeroes the average power meter.
Procedure Overview
1.
"Remove power from the RF IN/OUT connector." on page 37
.
RF IN/OUT connector.
2.
"Lower the Test Set’s output power if necessary." on page 38
.
Screen: CDMA GENERATOR CONTROL
Turn off:
Sector A Power
,
Sector B Power
,
AWGN
3.
"Select the Average Power measurement." on page 39
.
Screen: CDMA CELLULAR MOBILE TRANSMITTER TEST
Enter choice in:
Avg Power
4.
"Zero the Average Power measurement." on page 40
Screen: CDMA CELLULAR MOBILE TRANSMITTER TEST
Observe:
Power Meas
Manual Operation:
1. Press the CDMA SCRNS - TX TEST key to
display the CDMA CELLULAR MOBILE
TRANSMITTER TEST screen.
2. Position the cursor next to the Zero field.
3. Press the knob.
Zeroing Average Power takes approximately
two seconds.
CDMA CELLULAR MOBILE TRANSMITTER TEST
Zero
Power Meas
Avg Power
If RF power was not lowered as shown in step 2, the Test Set will display "Zero degraded. Reduce generator
level for best results" .