Install front mounting brackets and the load-bearing screws for rear mounting brackets.
Mount the router to the rack.
Supplied mounting brackets and the installation modes depend on your device
model.
MSR3012/3024
MSR3044
MSR3064
!
Router depth smaller
than rack depth.
Router depth greater than
rack depth
Exchange left and right rear
mounting brackets.
3
4
Connecting the Grounding Cable
Correctly connecting the router grounding cable is crucial to lightning protection
and EMI protection.
To connect the grounding cable when you mount the router on a workbench:
1. Connect one end of the grounding cable to the router and secure it with the
grounding screw supplied with the router.
2. Connect the other end of the grounding cable to a building grounding device.
If the installation site has no grounding strips, but earth ground is available,
hammer an angle iron or steel tube into the earth ground to serve as a
grounding conductor.
!
To connect the power cable
for rack-mounting:
1. Connect the building
grounding cable to the
grounding strip on the rack.
2. Connect one end of the
grounding cable to the
router and the other end to
the grounding strip on the
rack.
Make sure the rack is properly
grounded.