74
a.
Loosen the captive screws on the power monitoring module.
b.
Pull out the power monitoring module slowly along the slide rails.
Figure 53
Removing a power monitoring module
2.
Put the removed power monitoring module in an antistatic bag or in its original shipping materials.
3.
Install the new power monitoring module.
a.
Unpack a new power monitoring module.
b.
Insert the power monitoring module slowly along the slide rails until it fits in completely.
c.
Fasten the captive screws on the power monitoring module.
Figure 54
Installing the power monitoring module
Replacing a card
All cards of the 12500E are hot-swappable.
Preparing for the replacement
1.
Put on an ESD wrist strap, and make sure the wrist strap makes good skin contact and is correctly
grounded.
2.
Unpack the card to be installed. If the card has a protection cover, remove the protection cover.
Keep the removed protection cover for future use.
For more information about how to remove the protection cover, see "Installing the switch."
3.
Remove the network cables and power cords from the card to be removed.