B-2
Cabling and Technology Information
Because of the increased speed provided by 1000Base-T (Gigabit-T), network
cable quality is more important than for either 10Base-T or 100Base-TX.
Cabling plants being used to carry 1000Base-T networking must comply with
the IEEE 802.3ab standards. In particular, the cabling must pass tests for
Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must
pass tests for Equal-Level Far-End Crosstalk (ELFEXT) and Return Loss.
When testing your cabling, be sure to include the patch cables that connect
the switch and other end devices to the patch panels on your site. The patch
cables are frequently overlooked when testing cable and they must also
comply with the cabling standards.
Technology distance specifications
Table B-3.
Technology Distance Specifications
Technology
Supported cable type
Multimode fiber
modal bandwidth
Supported distances
100-FX
multimode fiber
any
up to 2,000 meters
100-BX
single mode fiber
N/A
0.5 - 10,000 meters
1000-T
twisted-pair copper
N/A
up to 100 meters
1000-SX
multimode fiber
160 MHz*km
200 MHz*km
400 MHz*km
500 MHz*km
2 - 220 meters
2 - 275 meters
2 - 500 meters
2 - 550 meters
1000-LX
multimode fiber
single mode fiber
400 MHz*km
500 MHz*km
N/A
2 - 550 meters
2 - 550 meters
2 - 10,000 meters
1000-LH
single mode fiber
N/A
10 - 70,000 meters
1
1000-BX
single mode fiber
N/A
0.5 - 10,000 meters
1
For distances less than 20km, a 10dB attenuator must be used. For distances between 20km and 40km, a 5dB
attenuator must be used. Attenuators can be purchased from most cable vendors.
Summary of Contents for E2620
Page 1: ...Power over Ethernet HP E2620 Switches Installation and Getting Started Guide ...
Page 2: ......
Page 3: ...HP E2620 Switches Installation and Getting Started Guide ...
Page 9: ...vii D Recycle Statements Waste Electrical and Electronic Equipment WEEE Statements D 1 Index ...
Page 10: ...viii ...
Page 78: ......
Page 98: ...C 8 Safety and EMC Regulatory Statements Safety Information China Safety Information China ...
Page 100: ...C 10 Safety and EMC Regulatory Statements EMC Regulatory Statements Korea Taiwan ...
Page 104: ...C 14 Safety and EMC Regulatory Statements EMC Regulatory Statements ...
Page 114: ...6 Index ...
Page 115: ......