Model
Keyboard(UH0G)/Mouse(MH0GC)/Dongle(DHN0)
Form No.: DFE0-01-001-04(030701)
6 Regulations and Certifications
6.1 EMI Test (conduction and radiation)
European Standard:
EN 55022: 2010/AC: 2011, Class B
.
Frequency Range of Test: From 30MHz to 1000 MHz
Test Distance: 10 M
Temperature: 15~35 ºC
Relative Humidity: 30~60 % RH
6.2 ESD Test
6.2.1 Keyboard unit:
Basic
standard:
EN55024:2010
Generic standard: IEC 61000-4-2:2008
Testing Criteria Air Discharge to EUT
Severity Level
Level +/-
Acceptance Criteria
1 4KV
B
2 8KV
B
3 10KV
B
4 12KV
B
5 15KV
C
Testing Criteria Contact Discharge to EUT
Severity Level
Level +/-
Acceptance Criteria
1 2KV
B
2 4KV
B
3 6KV
B
4 8KV
B
6.2.2 Mouse unit:
Basic
standard:
EN55024:2010
Generic standard: IEC 61000-4-2:2008
Testing Criteria Air Discharge to EUT
Severity Level
Level +/-
Acceptance Criteria
1 4KV
B
2 8KV
B
3 10KV
B