QuickSpecs
hp SANworks
Network View v2.0B
DA-10852
North America — Version 9 — August 1, 2002
4
S
O F T W A R E
P
R E R E Q U I S I T E S
(continued)
Host Agent Support: Network View requires host agent installation for Fibre Channel HBA (host bus adapter) discovery and monitoring purpose only. The
following table lists supported host operating systems and HBA firmware versions. Installable agents are provided with the Network View CD.
Server/Host
Systems
OS Versions
Associated HBAs
HBA Part
Number
HBA Firmware
Versions
HBA Driver
Versions
Windows 2000
SP2
HP StorageWorks 2 Gb, 64-bit/66 MHz
PCI-to-Fibre Channel Host Adapter for
Windows/NT, Windows 2000 (msa1000
only)
245299-B21
3.82a1 with boot
BIOS 1.60a5
5-4.81a9
Windows 2000
SP2
HP StorageWorks 64-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
176479-B21 3.82a1
5-4.81a9
Windows 2000
SP2
HP StorageWorks 32-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
380574-001 3.20x7 5-4.52a9
Windows 2000
(ProLiant only)
SP2
HP StorageWorks 64-bit/66 MHz PCI-to-
Fibre Channel Host Bus Adapter
120186-B21
No Firmware
5.4.6.63
Windows NT
v4.0 SP6a
HP StorageWorks 2 Gb, 64-bit/66 MHz
PCI-to-Fibre Channel Host Adapter for
Windows/NT, Windows 2000 (msa1000
only)
245299-B21 3.82a1 4-4.81a9
Windows NT
v4.0 SP6a
HP StorageWorks 64-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
176479-B21 3.82a1
4-4.81a9
Windows NT
v4.0 SP6a
HP StorageWorks 32-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
380574-001 3.20x7 4-4.52a9
Windows NT
(ProLiant only)
v4.0 SP6a
HP StorageWorks 64-bit/66 MHz PCI-to-
Fibre Channel Host Bus Adapter
120186-B21 No
Firmware 4.19.0.63
Windows 2000
for Datacenter
v2.0
HP StorageWorks 64-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
176479-B21 3.81a1 5-4.52a9
Tru64 UNIX
v5.1, v5.1A
HP StorageWorks 2 Gb, 64-bit/66 MHz
PCI-to-Fibre Channel Host Adapter for
Tru64 UNIX and OpenVMS (HSG80 only)
261329-B21 3.81A4
1.32A
Tru64 UNIX
v4.0F, v4.0G, v5.0a,
v5.1, v5.1a
HP StorageWorks 64-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter for Tru64
168794-B21
3.81a4
1.29
Tru64 UNIX
v4.0F, v4.0G, v5.0a,
v5.1, v5.1a
HP StorageWorks 32-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
380574-001 3.20x7
1.29
Solaris
v2.6, v7 or v8
(See Note 1)
HP StorageWorks 32-bit PCI-to-Fibre
Channel Host Bus Adapter for Solaris
380576-001 3.03
2.5.9
Solaris
v2.6, v7 or v8
(See Note 1)
HP StorageWorks 64-bit SBus-to-Fibre
Channel Host Bus Adapter for Solaris
123503-001 13.3.7
2.5.9
OpenVMS
v7.3, 7.3-1
HP StorageWorks 2 Gb, 64-bit/66 MHz
PCI-to-Fibre Channel Host Adapter for
Tru64 UNIX and OpenVMS (HSG80 only)
261329-B21 3.81A4
Embedded
in
OS
OpenVMS
v7.3, 7.3-1
HP StorageWorks 64-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
168794-B21 3.81a4
Embedded
in
OS
OpenVMS
v7.3, 7.3-1
HP StorageWorks 33-bit/33 MHz PCI-to-
Fibre Channel Host Bus Adapter
380574-001 3.20x7
Embedded
in
OS
HP-UX
v11.0
HP StorageWorks 64-bit/66 MHz PCI-to-
Fibre Channel Host Bus Adapter for HP-UX
216409-B21 1.4
2.5.8
AIX
v4.3.2, v4.3.3
HP StorageWorks 64-bit/66 MHz PCI-to-
Fibre Channel Host Bus Adapter for AIX
197819-B21 2.01.19
1.5.14.14,
1.5.15.1
NetWare
v4.2, v5.1, v6.0
HP StorageWorks 64-bit/66 MHz PCI-to-
Fibre Channel Host Bus Adapter
120186-B21 No
Firmware CPQFC.HA
M 2.52
Note 1:
The following patches need to be installed for the Solaris operating system:
Solaris v2.6: 105181-23, 105210-33, 105284-37, 105568-21, 105591-09, 105633-49, 105669-10, 106040-15, 106125-10, 106841-01, 106842-09,
107733-09, 108091-03.
Solaris v7: 106980-10, 107636-03, 106541-11, 107544-03, 109104-01, 106950-09, 106327-08, 106300-09, 107081-20.
Solaris v8: 108940-07.
The order of patch installation is dictated by the patch dependencies as documented by Sun
Microsystems for each patch. Patches can be
obtained from
http://access1.sun.com
.
However, patch 109104
−
* is no longer available from access1. This is because Sun has rolled the
functionality of 109104 into the latest kernel patch (106541-16). If a patch is not found or not up to the latest revision, a warning message is
displayed. In the case of the 109104 patch, the warning message can be safely ignored if 106541-16 or greater is installed.