background image

Multiple models for
flexible installation

The HP Remote Monitoring PDUs are available in four form factors for a variety of racks and environments.
All HP Remote Monitoring PDUs can be mounted to stay completely out of the critical rear maintenance
path needed to service IT equipment in the rack. All vertical models use industry standard button and
keyhole mounting for simple drop in installation in HP 11000 G2 and Intelligent Series racks and many
third party racks.

1U PDUs

Mounts in 1U of space in any EIA standard rack. Available in either a low voltage model with twelve NEMA
5-20 receptacles or high voltage models with twelve IEC C13 outlets.

Vertical PDUs

A variety of sizes meet the needs of many environments
Mounts vertically on either side in the rear of the rack using industry standard button and keyhole
mounting.
Standard mounting faces the outlet towards the rear of the rack. This configuration fully prevents
interference in the maintenance zone between rear RETMA rails.
Using the optional configuration of facing the outlets into the rack, multiple PDUs can be mounted
on one side of the rack for higher power density.

*

NOTE:

 Facing the outlets into the rack will interfere with the lower few rack U spaces of the rear

maintenance zone due to breakers on the PDUs.

Vertical PDU Form Factors

Half Height PDU

Designed to fit in 22U and taller racks
Up to 4 Half Height PDUs can be mounted in one side of a 42U or 47U rack using the optional
inward facing configuration.

Mid Height PDUs

Designed to fit in 36U and taller racks
New Three Phase Dual Voltage models provide three NEMA 5-20 convenience outlets for low
voltage equipment in high voltage racks.

Full Height PDUs

Designed for 42U and taller racks.

480V PDUs

Full height form factor for 42U and taller racks
480V three phase 5 wire input provides 277V single phase output.
Unique outlets prevent connection of non-277V compatible equipment.

NOTE:

 When mounted in the standard rear facing configuration only 1 Mid or Full Height PDU can be

mounted per side of the rack. Up to 2 Half Height PDUs can be mounted per side in the standard rear facing
configuration in a 42U or taller rack.

Environmental
monitoring

An optional environmental sensor attaches to the HP Remote Monitoring PDU and can measure air
temperature and humidity in the front or rear of the rack. The environmental senor will send alerts over
the network based on user defined thresholds.

QuickSpecs

HP Remote Monitored Power Distribution Units (mPDU)

Standard Features

DA - 14669   North America — Version 7 — May 9, 2014

Page  4

Summary of Contents for D9N44A

Page 1: ...dard button and keyhole mounting They can be installed on either side of the rack with outlets facing the back of the rack for easy access and improved clearance Also for higher power density they can be installed side by side on both sides of the rack with the outlets facing in towards the center of the rack HP Remote Monitored PDUs are available in 1U and vertical form factors in single and 3 ph...

Page 2: ...8 Volt L15 30 3 Phase Input 18xC13 3xC19 NA JP Monitored PDU D9N51A Full Height Models HP 8 3kVA 208 Volt CS8265C Input 30xC13 3xC19 NA Monitored PDU D9N49A HP 16 6kVA 400 Volt IEC309 30A 3 Phase Input 30xC13 3xC19 NA Monitored PDU D9N61A HP 17 3kVA 208 Volt IEC309 60A 3 Phase Input 24xC13 3xC19 NA JP Monitored PDU D9N54A HP 14 4kVA 208 Volt CS8365C 3 Phase Input 12xC13 12xC19 NA Monitored PDU D9N...

Page 3: ...A Billing grade accuracy All HP Remote Monitoring PDUs meet IEC 62053 21 Class 1 standards for 1 or better accuracy in power monitoring of Amperage Voltage Wattage Kilowatts per hour A LCD screen on the HP Remote Monitored PDU provides local monitoring and local alert indications Remote monitoring and management is available via Telnet or a standard web browser Flexible Software Easy to use CLI an...

Page 4: ...k will interfere with the lower few rack U spaces of the rear maintenance zone due to breakers on the PDUs Vertical PDU Form Factors Half Height PDU Designed to fit in 22U and taller racks Up to 4 Half Height PDUs can be mounted in one side of a 42U or 47U rack using the optional inward facing configuration Mid Height PDUs Designed to fit in 36U and taller racks New Three Phase Dual Voltage models...

Page 5: ... many third party racks Warranty Upgrade Options HP Remote Monitoring PDUs are backed by a limited 3 year warranty HP Remote Monitoring PDUs automatically assume the Care Pack coverage level of any covered ProLiant server in the same rack QuickSpecs HP Remote Monitored Power Distribution Units mPDU Standard Features DA 14669 North America Version 7 May 9 2014 Page 5 ...

Page 6: ...helping to deliver high level of application availability Response times range from 30 mins for critical problems to 2 hours System Management Performance Services and Mission Critical Support Solution NOTE For more information on HP Care Pack services contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at http www hp com hps carepack NOTE For mo...

Page 7: ... AS3112 3 AU NZ 250V 15Amp 3 6m Power Cord AF577A HP C19 IEC 309 DK SE AR 250V 16Amp 3 6m Power Cord AF581A HP C19 CEE VII EU 250V 16Amp 3 6m Power Cord AF576A HP C19 CEI 23 50 IT CL 250V 16Amp 3 6m Power Cord AF580A HP C19 SABS 164 ZA 250V 16Amp 3 6m Power Cord AF579A HP C19 BS 1363 A UK HK SG 250V 13Amp 3 6m Power Cord 359615 031 HP 240 VAC 4 5M Unterminated End NA Power Cord E7806A NOTE Please ...

Page 8: ...7 Volt 15Amp AC 1 37M Jumper Cord TK802A HP 800VA 277V Input 230V Output NA Rack Mount Transformer H3X09A NOTE 720 watt 2U transformer converts 277V to 230V for up to 4 devices NOTE Cord lengths listed are total length including connectors NOTE Please refer to the Power Cord Matrix for more information on power cords cable part numbers input output descriptions http www hp com go powercordmatrix H...

Page 9: ...C C13 Mid Height vertical models Model Part Number Input Voltage Current Maximum Load capacity Input Connection Output circuit breaker Outlet Connections 4 9kVA PDU D9N47A 200 240V 30A 24A 4992VA 208V 8ft 2 4m cord with attached NEMA L6 30P 2 x 20A 20 x IEC C13 4 x IEC C19 7 3kVA PDU D9N48A 200 240V 32A 32A 7360VA 230V 8ft 2 4m cord with attached IEC 332P6 Splashproof 2 x 16A 20 x IEC C13 4 x IEC ...

Page 10: ...0 208V 60A 3 Phase Delta 83 04A 17292VA 208V 3 Phase 8ft 2 4m cord with attached IEC 460P9 Splashproof 6 x 20A 24 x IEC C13 3 x IEC C19 22kVA PDU D9N56A 380 415V 32A 3 Phase WYE 32A phase 22080VA 400V 3 Phase 8ft 2 4m cord with attached IEC 532P6 Splashproof 6 x16A 30 x IEC C13 3 x IEC C19 14 4kVA PDU D9N58A 200 208V 50A 3 Phase Delta 69 28A 14410VA 208V 3 Phase 8ft 2 4m cord with attached CS8365C...

Page 11: ...refer to the Power Cord Matrix for more information on power cords cable part numbers input output descriptions http www hp com go powercordmatrix Disclaimer HP makes no recommendations regarding power connector manufactures Please consult a licensed professional to determine the best connector or receptacle for your specific needs QuickSpecs HP Remote Monitored Power Distribution Units mPDU Remot...

Page 12: ... Shipping bracket vertical models only 6ft RJ45 RJ45 communications cable 6ft RJ45 DB9 Serial cable Read me first card Environment friendly Products and Approach End of life Management and Recycling Hewlett Packard offers end of life HP product return trade in and recycling programs in many geographic areas For trade in information please go to http www hp com go green To recycle your product plea...

Page 13: ...t forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP Remote Monitored Power Distribution Units mPDU Technical Specifications DA 14669 North America Version 7 May 9 2014 Page 13 ...

Reviews: