C–6
371411-001
Service Reference Guide, dx2000 ST
POST Error Messages
1201-System Audio
Address Conflict
Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ.
1202-MIDI Port Address
Conflict Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ.
1203-Game Port
Address Conflict
Detected
Device IRQ address
conflicts with another
device.
Reset the IRQ
1720 SMART Hard
Drive Detect Imminent
Failure
Hard drive is about to
fail. (Some hard drives
have a firmware patch
that will fix an erroneous
error message.)
Determine if hard drive is giving correct
error message. Run the Drive Protection
System text if applicable.
Apply firmware patch if applicable. (see
)
Back up contents and replace hard drive.
1800-Temperature Alert Internal temperature
exceeds specification.
Check that computer air vents are not
blocked and cooling fan is running.
Verify processor speed selection.
Replace the processor.
Replace the system board.
1801-Microcode Patch
Error
Processor not supported
by ROM BIOS.
Upgrade BIOS to proper version.
1998-Master Boot
Record has been lost.
The previously saved
copy of the MBR has
been corrupted.
Run Computer Setup and save the MBR
of the current bootable disk.
1998-Master Boot
Record has been
changed.
The current MBR does not
match the previously
saved copy of the MBR.
Use extreme caution, The MBR may have
been updated due to normal disk
maintenance activities (disk manager,
fdisk, or format). Replacing the
previously saved MBR in such situations
can cause data loss. If certain that the
MBR change is unintentional and
undesired (e.g. due to a virus), run
Computer Setup and restore the
previously saved MBR copy. Otherwise,
run Computer Setup and either disable
MBR security or save the MBR of the
current bootable disk.
2000-Master Boot
Record Hard Drive has
Changed.
The current bootable hard
drive is not the same as
the one that was present
when MBR security was
enabled.
Run Computer Setup and either disable
MBR security or save the MBR of the
current bootable disk.
POST Error Messages
Screen Message
Probable Cause
Recommended Action
Summary of Contents for Compaq dx2000 ST
Page 2: ......
Page 8: ...vi 371411 001 Service Reference Guide dx2000 ST Contents ...
Page 54: ...4 8 371411 001 Service Reference Guide dx2000 ST Ultra ATA Drive Guidelines and Features ...
Page 110: ...C 8 371411 001 Service Reference Guide dx2000 ST POST Error Messages ...
Page 144: ...F 4 371411 001 Service Reference Guide dx2000 ST Memory ...
Page 150: ...Index 6 371411 001 Service Reference Guide dx2000 ST ...