HP Clemco 60 Release Note Download Page 5

Fixes

Implemented a Single Cycle Hold Detection (SCHD) fix for SATA drives.

Fixed an intermittent issue which resulted in MSA60/70 enclosures sending a BREAK primitive
(sometimes referred to as a “SAS Link Broken” issue) to SmartArray and MSA array controllers.

Fixed issues which resulted in a hung I/O module with blinking amber LEDs.

Fixed an intermittent issue which resulted in MSA60/70 enclosures sending broadcast messages
to the initiator, causing a temporary performance reduction.

Fixed an intermittent issue where the enclosure returned incorrect Initiator Connection Tag (ICT)
information to the initiator.

Incorporated other minor miscellaneous firmware enhancements and fixes.

Important notes

IMPORTANT:

If currently-installed MSA70 firmware version is less than 1.50, you must first obtain a new
backplane to perform this update.

If currently-installed MSA70 firmware version is less than 2.00, you must perform this update with
only one I/O module inserted at a time.

NOTE:

After the firmware has been updated, you must power cycle each enclosure to complete the

update process. This is applicable to both server-attached and controller-enclosure-attached
configurations.

Installation instructions

When planning for a firmware upgrade, select and schedule an appropriate time to perform an online
upgrade. For single domain systems, I/O must be halted. For dual domain systems, when performing
an online upgrade, selecting the appropriate time is essential. Because the online firmware upgrade
is performed while host I/Os are being serviced, the I/O load can impact the upgrade process.
Selecting a period of low I/O activity will ensure the upgrade completes as quickly as possible, and
will avoid disruptions to hosts and applications due to timeouts.

WARNING!

Do not power cycle the enclosure during the updating process or restart the update

process once begun. This can result in loss of capabilities for the unit.

CAUTION:

Before upgrading controller firmware, ensure that the storage system configuration is

stable and is not being reconfigured or changed in any way. If configurations changes are in progress,
monitor them and wait until they are completed before proceeding with the upgrade.

IMPORTANT:

As with any firmware upgrade, it is a recommended best practice to ensure that you

have a full backup prior to the upgrade.

NOTE:

To download this module from the HP website, right-click the link and save the file to your

local filesystem. You cannot double-click the link.

Fixes

5

Summary of Contents for Clemco 60

Page 1: ...HP 60 70 Modular Smart Array Enclosure Firmware 2 28 Release Notes HP Part Number 536920 006 Published May 201 1 Edition Sixth ...

Page 2: ... Copyright 2009 201 1 Hewlett Packard Development Company L P ...

Page 3: ...ported companion firmware versions for array controller enclosures and drive enclosures see Controller enclosures controller firmware and MSA70 firmware versions page 3 Controller enclosure connect Supersedes 2 18 Product models HP 60 Modular Smart Array drive enclosure MSA60 HP 70 Modular Smart Array drive enclosure MSA70 Controller enclosures controller firmware and MSA70 firmware versions The f...

Page 4: ...ition non program Datacenter Windows HPC Server 2008 Microsoft Windows Server 2003 R2 Std EE both 32 64 bit Microsoft Windows Server 2003 R2 SBS Microsoft Windows Server 2003 R2 Web Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows Server 2003 on Itanium Novell NetWare 6 5 Open Enterprise Server Open VMS V8 3 1H Red Hat Enterp...

Page 5: ... enclosure attached configurations Installation instructions When planning for a firmware upgrade select and schedule an appropriate time to perform an online upgrade For single domain systems I O must be halted For dual domain systems when performing an online upgrade selecting the appropriate time is essential Because the online firmware upgrade is performed while host I Os are being serviced th...

Page 6: ...P USB Key utility from the HP Support and Drivers download page http www hp com support 2 Copy necessary firmware Smart Component files to the following USB driver folder nl hp swpackages 3 Boot the server from the bootable CD or USB key 4 Follow HP Smart Update Manager on screen instructions to complete the firmware update NOTE Installation will take approximately 8 to 10 minutes per enclosure Fo...

Page 7: ... navigate to the directory containing the download 3 Double click the executable file 4 Follow onscreen instructions NOTE When prompted for logon information enter credentials for an account with management access rights CLI option The following syntax can be used to invoke at the command line cpxxxxxxx exe target ip_address user username passwd password s where ip_address is the management IP add...

Page 8: ...wnloaded file 4 Execute the Smart Component by entering a command similar to the following CPxxxxxx scexe target ip_address user manage_username passwd password If the user name or password contains an exclamation mark enclose the string in single quotes or enter a backslash before the exclamation point For example manage or manage 5 Follow onscreen instructions NOTE When prompted for logon inform...

Reviews: