To install the device on the rails and into the rack:
1.
Locate the captive screws on the front bezel (see
).
2.
Slide the device onto the rails.
3.
From the front of the device, secure the front bezel to the rack using a #2 Phillips screw driver
placed through the small holes in the mounting bracket to tighten the captive screws on each
side of the device.
Figure 15 Securing the Autoloader to the rack
Installing the Tabletop Conversion Kit
If you do not have the optional Tabletop Conversion Kit, skip this step and continue with
the SCSI cable (parallel SCSI devices only)
. The Rack to Tabletop Conversion Kit supports the
edges of the Tape Autoloader and is capable of holding 15 kg (33 lb).
To install the cover:
1.
Place the cover on a flat, level surface behind the device.
2.
Slide the device into the cover until the front panel of the device is aligned with the cover (see
).
Figure 16 Installing the tabletop conversion cover
3.
Tighten the captive screws on the front panel until the cover is secure.
Changing the SCSI address (parallel SCSI drives only)
If you have multiple parallel SCSI devices on the SCSI bus and another device is already using
SCSI ID 4, you must change the SCSI ID of the Autoloader.
To change the SCSI ID:
Installing the Tabletop Conversion Kit
25
Summary of Contents for BL536A
Page 149: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 149 ...
Page 151: ...Danish notice Dutch notice Estonian notice Finnish notice French notice Recycling notices 151 ...
Page 155: ...French battery notice German battery notice Battery replacement notices 155 ...
Page 156: ...Italian battery notice Japanese battery notice 156 Regulatory compliance and safety ...