This method forces the server to enter standby mode without properly exiting applications and the OS.
If an application stops responding, you can use this method to force a shutdown.
• Use a virtual power button selection through iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server
enters standby mode.
Before proceeding, verify that the server is in standby mode by observing that the system power LED is
amber.
Extend the drive drawer from the chassis
WARNING:
Do not keep the drive drawer open for more than three minutes. Keeping the drawer open for longer
than three minutes can cause the system to shut down due to overheating.
NOTE:
Keeping the drawer open might result in reduced system performance or thermal shutdown.
CAUTION:
Do not open more than one drive drawer at a time.
Procedure
Extend the drive drawer from the chassis as indicated.
Extend the drive drawer from the chassis
25