With second
H7609
4
0 or 2
2
5
0
0
NOTES
NOTES
NOTES
NOTES:
a. Installation of only one AlphaServer ES45 system in an H9A15 cabinet requires the mandatory selection of a ballast kit.
b. H9A1x-ME includes one H7609-EB PDU; H9A1x-MF includes one H7609-DB PDU - Order second PDU.
- Single Input - 3X-H7609-DB/EB, 240V
- Dual Input - 3X-H7609-DB/EB, 240V
M-Series Cabinets
M-Series Cabinets
M-Series Cabinets
M-Series Cabinets -
Specify cabinet selection
67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 200-
240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P,
Americas, Asia Pacific; includes rear door.
H9A10-ME
67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 240V
dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe;
includes rear door.
H9A10-MF
79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 200-
240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P,
Americas, Asia Pacific; includes rear door.
H9A15-ME
79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 240V
dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe;
includes rear door.
H9A15-MF
Rear Cabinet Extender
Rear Cabinet Extender
Rear Cabinet Extender
Rear Cabinet Extender -
Mandatory based on
cabinet height
Rear cabinet extender for carbon black H9A10 cabinets
H9C10-ZE
Rear cabinet extender for carbon black H9A15 cabinets
H9C15-ZE
Front Cabinet Treatment
Front Cabinet Treatment
Front Cabinet Treatment
Front Cabinet Treatment -
Mandatory based on
cabinet height
Front door for carbon black H9A10 cabinet enclosure
3X-H9C10-RF
Front trim kit for carbon black H9A10 cabinet enclosure
H9C10-ZT
Front door for carbon black H9A15 cabinet enclosure
3X-H9C15-RF
Front trim kit for carbon black H9A15 cabinet enclosure
H9C15-ZT
Factory Integration
Factory Integration
Factory Integration
Factory Integration -
Mandatory
Factory Integration of systems and storage devices assembled and configured in
cabinet enclosure in predefined locations
YS-ASCAA-AA
Ballast Kit
Ballast Kit
Ballast Kit
Ballast Kit - Mandatory if
only one ES45 system
drawer is ordered for the
H9A15 cabinet
Ballast is added to a cabinet at particular locations for specific configurations to
meet safety regulations for installation, operation, and service; see Cabinet
Configuration Charts.
Two 35–40 lb (16–18 kg) steel plates
H9C10-MC
Power Distribution Unit -
Power Distribution Unit -
Power Distribution Unit -
Power Distribution Unit -
Mandatory
Single Phase, Double Power Controller, 16 outlet North America/Japan 240V
3X-H7609-EB
Single Phase, Double Power Controller, 16 outlet, Europe 240V
3X-H7609-DB
QuickSpecs
HP AlphaServer ES45
HP AlphaServer ES45
HP AlphaServer ES45
HP AlphaServer ES45
Options
DA - 10994 North America — Version 59 — May 7, 2007
Page 14