With two load segments, you have the flexibility to configure scheduled startups and shutdowns, in
addition to independently control the separate load segments. Working in conjunction with HP Power
Management Software, the HP UPS R5500 can be configured to extend the runtime for more critical
devices.

Ease of Maintenance with

Ease of Maintenance with

Ease of Maintenance with

Ease of Maintenance with
Hot-Swappable Batteries

Hot-Swappable Batteries

Hot-Swappable Batteries

Hot-Swappable Batteries
and Electronics Modules

and Electronics Modules

and Electronics Modules

and Electronics Modules

The UPS R5500 is modular in design, and both the battery and the electronics modules are hot
swappable. HP UPSs are designed with simple access through the front panel. Users can safely install
new batteries and even the electronics module without ever powering down connected server and server
options.

HP Quality

HP Quality

HP Quality

HP Quality

HP's hardware qualification is the toughest in the industry. Extensive evaluation, testing, product
improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical
performance, product quality and compatibility.

Compatibility

Compatibility

Compatibility

Compatibility

Compatible with all HP servers, storage, racks, rack options, and other rack mountable HP equipment.
For PDU options please refer to the UPS/PDU compatibility matrix on 

www.hp.com/products/ups

.

Warranty

Warranty

Warranty

Warranty

The HP UPS R5500 is covered by a three year warranty, with the first year including parts and labor.
Also, standard on all HP UPS units, is our exclusive Pre-Failure Warranty, which extends the advantage of
a HP three-year, limited warranty by applying it to the battery before it actually fails. This warranty is
offered worldwide. Specifically, the Pre-Failure Battery Warranty ensures that when customers receive
notification from HP Power Management Software that the battery may fail, the battery is replaced free of
charge under the warranty.

NOTE:

NOTE:

NOTE:

NOTE: $250,000 Computer/Load Protection Guarantee is also provided in NA, in addition to the HP
three year, limited warranty.

QuickSpecs

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

Standard Features

DA - 11871   Worldwide — Version 21 — January 9, 2012

Page 4

Summary of Contents for AF416A

Page 1: ...eir UPS R5500 by using this ERM The HP UPS models denote Extended Runtime Capable UPS models 1 REPO port 7 Load segment 2 two IEC 320 C19 receptacles and two IEC 320 C13 receptacles 2 Ground bonding screw 8 Battery circuit breaker 3 Communications port option slot 9 Cord retention clip attach locations 4 Load segment 1 circuit breaker 10 ERM connector 5 Load segment 1 two IEC 320 C19 receptacles a...

Page 2: ...ules Modules The Extended Runtime Modules are rack mounted battery modules that occupy 3U 5 25 inches of rack space The HP UPS R5500 supports up to four Extended Runtime Modules ERM which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership with Innovative with Innovative with Innovative with Innovative Technology Techn...

Page 3: ...cating 76 to 100 load capacity 10 ON Button 3 LED indicating 51 to 75 load capacity 11 General Alarm 4 LED indicating 26 to 50 load capacity 12 On Battery 5 LED indicating 0 to 25 load capacity 13 Bad Battery Low Battery 6 Configure mode on LED 14 Site Wiring Fault Indicator 7 Configure Button 15 Utility LED 8 TEST ALARM RESET Button A Voltage Configuration Panel Accessible only when the front bez...

Page 4: ...n the industry Extensive evaluation testing product improvement and an unsurpassed warranty guarantee the highest level of system protection electrical performance product quality and compatibility Compatibility Compatibility Compatibility Compatibility Compatible with all HP servers storage racks rack options and other rack mountable HP equipment For PDU options please refer to the UPS PDU compat...

Page 5: ...er For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within the same rack NOTE NOTE NOTE NOTE For more information on HP Care Pack Services contact any of our worldwide sales offices or resellers or visit our worldwide web site on the internet at http www hp com hps carepack NOTE NOTE NOTE NOTE For more complete information on HP Ser...

Page 6: ...ration Management of the UPS from anywhere and at anytime via a standard web browser NOTE NOTE NOTE NOTE For more information on the UPS Management Module please see http h18004 www1 hp com products servers proliantstorage powerprotection software module ups index html web browser Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM R5500 ERM R5500 ER...

Page 7: ... AF402A HP R5500 VA Extended Runtime Module NOTE NOTE NOTE NOTE 0D1 will appear after the part number on the sales order if HP factory integration is indicated AF417A HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP Rack Mountable R5500 UPS HP Rack Mountable R5500 UPS HP Rack Mo...

Page 8: ...ed receptacle LS1 1 x L6 30R for NA JPN model AF416A International 220 230 240 if set at 200 208 6000 5400 then 5000 4500 IEC 309 32Amp 3m cord LS1 15A CB 2 x C19 2 x C13 LS2 15A CB 2 x C19 2 x C13 Plus one pigtailed receptacle LS1 1 x IEC 309 32Amp for Int l model Factory default setting Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R5500 HP Power Management Software CD Power Product...

Page 9: ... Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Load Percent Load Percent Load Percent Load Percent With Standby Battery With Standby Battery With Standby Battery With Standby Battery Minutes Minutes Minutes Minutes With One Extended With One Extended With One Extended With One Extended Runtime Module Runtime Module Runtime M...

Page 10: ...cid VRLA Extended Batteries Extended Batteries Extended Batteries Extended Batteries Up to four ERMs supported Backup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Battery String Voltage Battery String Voltage Battery String Voltage Battery String Voltage 240V Batt...

Page 11: ... please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product d...

Reviews: