![HP AA-RS2WC-TE Installation Manual Download Page 177](http://html.mh-extra.com/html/hp/aa-rs2wc-te/aa-rs2wc-te_installation-manual_165815177.webp)
Technical Specifications
177
Core Switch 2/64 V4.1 Installation Guide
Environmental Requirements
lists the environmental operating ranges for the Core Switch 2/64. The
requirements for nonoperating conditions are also provided.
Note:
The 0
° −
40
°
C temperature range listed in
represents the ambient
temperature at the air intake vents on the non-port side of the switch. Individual
components may have a higher range. For example, the 16-port cards and CP cards
have a temperature range up to 75
°
C. Use the
tempShow
command to show the true
temperature of each individual component.
Table 17: Environmental Requirements
Condition
Acceptable Range
During Operation
Acceptable Range During
Non-Operation
Ambient
Temperature
0
°
to 40
°
Celsius outside
switch
(50
°
to 104
°
Farenheit
)
-25
°
to +70
°
Celsius outside
switch
(-13
°
to 158
°
Farenheit)
Humidity
20% to 85% RH
non-condensing, at
40× Celsius, with maximum
gradient of 10% per hour
10% to 85% RH non-condensing, at
70° Celsius
Altitude
0 to 3 kilometers above sea
level
(0 to 10,000 feet altitude)
0 to 12 kilometers above sea level
(0 to 39,370 feet)
Shock
4G, 11MS duration,
half-sine wave
20G, 11MS duration, sq. wave
Vibration
5G, 0-3 kHz at 1.0
octave/minute
10G, 0-5 kHz at 1.0 octave/minute
Heat
Dissipation
64 ports: 3690 BTU/hr
128 ports: 6700 BTU/hr
Not applicable
Summary of Contents for AA-RS2WC-TE
Page 12: ...Contents 12 Core Switch 2 64 V4 1 Installation Guide ...
Page 34: ...Overview 34 Core Switch 2 64 V4 1 Installation Guide ...
Page 88: ...Installing and Configuring the Core Switch 2 64 88 Core Switch 2 64 V4 1 Installation Guide ...
Page 168: ...Running Routine Operations 168 Core Switch 2 64 V4 1 Installation Guide ...
Page 198: ...Technical Specifications 198 Core Switch 2 64 V4 1 Installation Guide ...
Page 224: ...Setting Up and Configuring Modems 224 Core Switch 2 64 V4 1 Installation Guide ...