The first step in problem-solving is establishing whether the problem lies with the cartridge, the
drive, the host server and its connections, or with the way the system is being operated.
Most modern SCSI host bus adapters locate and display attached devices when the system is
booting up. On Windows systems, if you swap or connect a product when your system is
running, you will need to reboot the system. IA32 systems also usually need to be rebooted.
UNIX systems may have pluggable drivers, which allow drives to be attached to a running
system and detected without rebooting.
If the device is not detected on boot up, there is probably a problem with the physical
hardware: cables, termination, connections, power or the host bus adapter itself. If the device
is displayed during boot up but cannot be found in the operating system, this is more likely to
be a software problem.
• If you encounter a problem during installation and need further clarification, refer to the
“Problems encountered during installation” on page 37.
• If a problem arises during testing after you have installed the drive, refer to the symptom-
based section “Testing after installation” on page 39.
• For more information about LED sequences, refer to “Understanding the LEDs” on page 41.
• For information about cartridges, refer to “Problems with cartridges” on page 43.
Users of most operating systems can use HP Library & Tape Tools to help them diagnose
problems.
sdlt600_master_frame6.fm Page 36 Monday, April 5, 2004 1:18 PM
Summary of Contents for A7518B - StorageWorks SDLT 600 Tape Drive
Page 1: ...getting started guide hp StorageWorks SDLT tape drive internal model SDLT 600i ...
Page 2: ...open this flap for quick start installation poster ...
Page 3: ...1 4 5 ...
Page 4: ...2 3 6 ...
Page 20: ...16 hp SDLT 600 StorageWorks Figure 6 installing the drive ...
Page 51: ......
Page 52: ...http www hp com go storagemedia http www hp com support tape AA984 90902 ...