HP A5820X-24XG-SFP+ Datasheet Download Page 5

5

HP A5820 Switch Series

Specifications

HP A5820X-14XG-SFP+ Switch with 2 Interface Slots and 1 OAA Slot (JC106A)

HP A5820X-24XG-SFP+ Switch (JC102A)

Ports

14 SFP+ 10-GbE ports; Duplex: full only

2 extended module slots

1 open module slot

4 RJ-45 auto-negotiating 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE
802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)

1 RJ-45 serial console port

Supports a maximum of 14 SFP+ ports plus 8 8/4/2 Gbps Fibre Channel SFP+
ports, with optional module

24 SFP+ 10-GbE ports; Duplex: full only

4 RJ-45 auto-negotiating 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE
802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)

1 RJ-45 serial console port

Supports a maximum of 24 SFP+ ports plus 4 autosensing 10/100/1000 ports

Power supplies

2 power-supply slots
1 minimum power-supplies required (ordered separately)

2 power-supply slots
1 minimum power-supplies required (ordered separately)

Fan tray

includes: 1 x JC096A
1 fan tray slot
Base product includes fan tray

includes: 1 x JC096A
1 fan tray slot
Base product includes fan tray

Physical characteristics

Dimensions

18.39(d) x 17.32(w) x 3.39(h) in. (46.7 x 43.99 x 8.61 cm) (2U height)

16.81(d) x 17.32(w) x 1.73(h) in. (42.7 x 44.0 x 4.4 cm) (1U height)

Weight

33.29 lb. (15.1 kg)

18.74 lb. (8.5 kg)

Memory and processor

512 MB SDRAM, 512 MB flash; packet buffer size: 2 MB

512 MB SDRAM, 512 MB flash; packet buffer size: 2 MB

Performance

Throughput

up to 363 million pps (64-byte packets)

up to 363 million pps (64-byte packets)

Routing/Switching capacity

488 Gbps

488 Gbps

Routing table size

12000 entries

12000 entries

MAC address table size

32000 entries

32000 entries

Environment

Operating temperature

32°F to 113°F (0°C to 45°C)

32°F to 113°F (0°C to 45°C)

Operating relative humidity

10% to 90%, noncondensing

10% to 90%, noncondensing

Electrical characteristics

Maximum heat dissipation

836 BTU/hr (881.98 kJ/hr)

631 BTU/hr (665.71 kJ/hr)

Voltage

100-120 / 200-240 VAC

100-120 / 200-240 VAC

Frequency

50 / 60 Hz

50 / 60 Hz

Safety

UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance

UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance

Emissions

VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003;
AS/NZS CISPR22 Class A; EN 61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15)
Class A

VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003;
AS/NZS CISPR22 Class A; EN 61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15)
Class A

Immunity

Generic

ETSI EN 300 386 V1.3.3

ETSI EN 300 386 V1.3.3

EN

EN 55024:1998+ A1:2001 + A2:2003

EN 55024:1998+ A1:2001 + A2:2003

ESD

EN 61000-4-2; IEC 61000-4-2

EN 61000-4-2; IEC 61000-4-2

Radiated

EN 61000-4-3; IEC 61000-4-3

EN 61000-4-3; IEC 61000-4-3

EFT/Burst

EN 61000-4-4; IEC 61000-4-4

EN 61000-4-4; IEC 61000-4-4

Surge

EN 61000-4-5; IEC 61000-4-5

EN 61000-4-5; IEC 61000-4-5

Conducted

EN 61000-4-6; IEC 61000-4-6

EN 61000-4-6; IEC 61000-4-6

Power frequency magnetic field

IEC 61000-4-8; EN 61000-4-8

IEC 61000-4-8; EN 61000-4-8

Voltage dips and interruptions

EN 61000-4-11; IEC 61000-4-11

EN 61000-4-11; IEC 61000-4-11

Harmonics

EN 61000-3-2, IEC 61000-3-2

EN 61000-3-2, IEC 61000-3-2

Flicker

EN 61000-3-3, IEC 61000-3-3

EN 61000-3-3, IEC 61000-3-3

Management

IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager; Telnet; HTTPS; RMON1; FTP

IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager; Telnet; HTTPS; RMON1; FTP

Notes

Customer must order a power supply, as the device does not come with a PSU.
At least one JC087A or JC090A is required.

Customer must order a power supply, as the device does not come with a PSU.
At least one JC087A or JC090A is required.

Summary of Contents for A5820X-24XG-SFP+

Page 1: ...ices into the network consolidating devices and appliances to simplify deployment and reduce power consumption and rack space Extremely versatile the switches can be used in high performance high density building or department cores as part of a consolidated network for data center top of rack server access or as high performance Layer 3 10 GbE aggregation switches in campus and data center networ...

Page 2: ... diverse applications based on the consistent time Connectivity High density port connectivity 194 10 GbE ports with a 40 Gbps resilient backplane Data center I O consolidation the A5820 14XG FCoE module supports two 4x8 4 2 Gbps FCoE modules up to eight FC ports total to reduce cost and complexity while boosting network performance Auto MDIX automatically adjusts for straight through or crossover...

Page 3: ...upport provides complete support of OSPF for both IPv4 and IPv6 IS IS and IS ISv6 support provides complete support of IS IS for both IPv4 and IPv6 Layer 3 IPv6 routing provides routing of IPv6 at media speed supports static routes RIPng OSPFv3 IS ISv6 and BGP4 Bidirectional Forwarding Detection BFD enables link connectivity monitoring and reduces network convergence time for RIP OSPF BGP IS IS VR...

Page 4: ...in the last mile monitors the status of the link between the two devices CFD 802 1ag connectivity fault detection CFD provides a Layer 2 link OAM operations administration and maintenance mechanism used for link connectivity detection and fault locating Additional information Intelligent Resilient Framework IRF Creates virtual resilient switching fabrics where two or more switches perform as a sin...

Page 5: ... 100 120 200 240 VAC 100 120 200 240 VAC Frequency 50 60 Hz 50 60 Hz Safety UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN CSA C22 2 No 60950 1 Anatel ULAR GOST EN 60950 1 A11 FDA 21 CFR Subchapter J NOM ROHS Compliance UL 60950 1 EN 60825 1 Safety of Laser Products Part 1 EN 60825 2 Safety of Laser Products Part 2 IEC 60950 1 CAN C...

Page 6: ...e Layer OAM IEEE 802 1D MAC Bridges IEEE 802 1p Priority IEEE 802 1Q VLANs IEEE 802 1s MSTP IEEE 802 1v VLAN classification by Protocol and Port IEEE 802 1w Rapid Reconfiguration of Spanning Tree IEEE 802 1X PAE IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 3ae 10 Gigabit Ethernet IEEE 802 3x Flow Control RFC 768 UDP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 854 TELNET RFC 925 Multi ...

Page 7: ...ansceiver JD092B HP X130 SFP LC LRM Transceiver JD093B HP X130 SFP LC LR Transceiver JD094B HP X240 SFP SFP 0 65 m Direct Attach Cable JD095B HP X240 SFP SFP 1 2 m Direct Attach Cable JD096B HP X240 SFP SFP 3 m Direct Attach Cable JD097B Cables NEW HP 0 5 m PremierFlex OM3 LC LC Optical Cable BK837A NEW HP 1 m PremierFlex OM3 LC LC Optical Cable BK838A NEW HP 2 m PremierFlex OM3 LC LC Optical Cabl...

Reviews: