5
HP A5820 Switch Series
Specifications
HP A5820X-14XG-SFP+ Switch with 2 Interface Slots and 1 OAA Slot (JC106A)
HP A5820X-24XG-SFP+ Switch (JC102A)
Ports
14 SFP+ 10-GbE ports; Duplex: full only
2 extended module slots
1 open module slot
4 RJ-45 auto-negotiating 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE
802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
1 RJ-45 serial console port
Supports a maximum of 14 SFP+ ports plus 8 8/4/2 Gbps Fibre Channel SFP+
ports, with optional module
24 SFP+ 10-GbE ports; Duplex: full only
4 RJ-45 auto-negotiating 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE
802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
1 RJ-45 serial console port
Supports a maximum of 24 SFP+ ports plus 4 autosensing 10/100/1000 ports
Power supplies
2 power-supply slots
1 minimum power-supplies required (ordered separately)
2 power-supply slots
1 minimum power-supplies required (ordered separately)
Fan tray
includes: 1 x JC096A
1 fan tray slot
Base product includes fan tray
includes: 1 x JC096A
1 fan tray slot
Base product includes fan tray
Physical characteristics
Dimensions
18.39(d) x 17.32(w) x 3.39(h) in. (46.7 x 43.99 x 8.61 cm) (2U height)
16.81(d) x 17.32(w) x 1.73(h) in. (42.7 x 44.0 x 4.4 cm) (1U height)
Weight
33.29 lb. (15.1 kg)
18.74 lb. (8.5 kg)
Memory and processor
512 MB SDRAM, 512 MB flash; packet buffer size: 2 MB
512 MB SDRAM, 512 MB flash; packet buffer size: 2 MB
Performance
Throughput
up to 363 million pps (64-byte packets)
up to 363 million pps (64-byte packets)
Routing/Switching capacity
488 Gbps
488 Gbps
Routing table size
12000 entries
12000 entries
MAC address table size
32000 entries
32000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
32°F to 113°F (0°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing
10% to 90%, noncondensing
Electrical characteristics
Maximum heat dissipation
836 BTU/hr (881.98 kJ/hr)
631 BTU/hr (665.71 kJ/hr)
Voltage
100-120 / 200-240 VAC
100-120 / 200-240 VAC
Frequency
50 / 60 Hz
50 / 60 Hz
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety
of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003;
AS/NZS CISPR22 Class A; EN 61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15)
Class A
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003;
AS/NZS CISPR22 Class A; EN 61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15)
Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC 61000-4-2
EN 61000-4-2; IEC 61000-4-2
Radiated
EN 61000-4-3; IEC 61000-4-3
EN 61000-4-3; IEC 61000-4-3
EFT/Burst
EN 61000-4-4; IEC 61000-4-4
EN 61000-4-4; IEC 61000-4-4
Surge
EN 61000-4-5; IEC 61000-4-5
EN 61000-4-5; IEC 61000-4-5
Conducted
EN 61000-4-6; IEC 61000-4-6
EN 61000-4-6; IEC 61000-4-6
Power frequency magnetic field
IEC 61000-4-8; EN 61000-4-8
IEC 61000-4-8; EN 61000-4-8
Voltage dips and interruptions
EN 61000-4-11; IEC 61000-4-11
EN 61000-4-11; IEC 61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
EN 61000-3-3, IEC 61000-3-3
Management
IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager; Telnet; HTTPS; RMON1; FTP
IMC - Intelligent Management Center; command-line interface; Web browser;
SNMP Manager; Telnet; HTTPS; RMON1; FTP
Notes
Customer must order a power supply, as the device does not come with a PSU.
At least one JC087A or JC090A is required.
Customer must order a power supply, as the device does not come with a PSU.
At least one JC087A or JC090A is required.