Appendix A Product Specifications
Order Number: EK–STWCT–UG. E01
A–3
SCSI Command Set (
Cont'd
)
Mode Sense
Load/Unload
Receive Diagnostic Results
Send Diagnostics
Prevent/Allow Medium Removal
Verify
Locate
Read Position
Log Sense/Log Select
Environment
Operating temperature: +5
°
C to +40
°
C (+41
°
F to 104
°
F)
Non-operating temperature: -40
°
C to +60
°
C (-40
°
F to +140
°
F)
Relative humidity (noncondensing): 20% to 80%
SCSI Characteristics
SCSI-2 Specification — ANSI X3.131-1990
Sequential Access Device
SCSI Bus Parity — Configurable
Full Disconnect, Arbitration, Reconnect
Asynchronous and Synchronous Data Transfer Supported
Connector Type — Standard StorageWorks Connector
Termination — None
Single-Ended
Physical Dimensions (Tape Device)
Standard 5.25-inch half-high form factor
Height: 1.625 inch
Width: 5.750 inch
Depth: 8.0 inch
Weight: 2.57 pounds
Power (For One Tape Device)
+5/ +12 volts plus or minus 5%
15 watts