24
DRAFT
Operation and Service Manual
Performance Tests Procedures
VSWR Test Procedure
Specifications,
VSWR:
Description:
A network analyzer is swept, in steps, from 1 to 1300 MHz (or 1400 MHz). At
each step the analyzer display is referenced to 1 dB return loss by shorting its out-
put. The short is then removed and the amplifier return loss is measured at the
INPUT and OUTPUT.
Equipment:
Sweep oscillator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8620A/8621A
Generator/sweeper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8601A
Network analyzer (0.1 to 110 MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8407A
Network analyzer (0.11 to 1.4 GHz) . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8410A
Phase-magnitude displayHP 8412A
Harmonic frequency converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8411A
S-parameter test set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 8745A
Universal extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 11604A
Transmission kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 11651A
Accessory kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 11570A
Cable assembly (3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 10503A
Cable assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP 11500A
HP 8447D
Preamp
(1 to 1300
MHz)
HP 8447E
Power Amp
(0.75 to 1400
MHz)
HP 8447F
Preamp
Power Amp
(1 to 1300 MHz)
(0.75 to 1400
MHz)
HP 8447F H64
Preamp
Low Freq Preamp
(1 to 1300 MHz)
(1 to 50 MHz)
<2.0 Input
<2.2 Input
<2.0 Input
<2.2 Input
<2.0 Input
<2.0 Input
<2.2 Output
<2.5 Output
<2.2 Output
<2.5 Output
<2.2 Output
<2.2 Output