Troubleshooting the MSD
Error messages
85
Difficulty with the fan
If a cooling fan fault occurs, the vacuum control electronics automatically shut off
the high vacuum pump and the ion source and mass filter heaters. Therefore, the
message:
The system is in vent state
may also appear. It is important to note that
even though the high vacuum pump is off, the vacuum manifold may not actually
be vented. See
The system is in vent state
in this section for precautions to take.
•
One of the fans is disconnected
•
One of the fans has failed
•
MSD electronics are not working correctly
Difficulty with the HED supply
•
Large peak such as the solvent peak eluted while the analyzer was on
•
Pressure in the vacuum manifold is too high
•
Bad cable connection between the detector and the MSD electronics
•
Detector is not working correctly
•
MSD electronics are not working correctly
Difficulty with the high vacuum pump
In an MSD equipped with a diffusion pump, this indicates the diffusion pump
became too hot. In an MSD equipped with a turbomolecular pump, this indicates
the pump failed to reach 50% of full speed in a preset time or experienced a fault.
You must switch the MSD off and back on to remove this error message. Be sure
the diffusion pump has cooled or the turbo pump has slowed down before switch-
ing off the MSD. The message will reappear if the underlying problem has not
been corrected.
Diffusion pump
•
Cooling fan for the high vacuum pump is not working
•
Air intakes to the cooling fan are blocked
•
Laboratory temperature is too high (generally above 35°C)
•
High vacuum signal cable is disconnected or not working correctly
•
Diffusion pump temperature sensor is not working correctly
•
MSD electronics are not working correctly
Summary of Contents for 5973
Page 1: ...H Hardware Manual HP 5973 Mass Selective Detector ...
Page 3: ...HP 5973 Mass Selective Detector Hardware Manual ...
Page 25: ...1 Installing GC Columns To condition a capillary column 25 ...
Page 30: ...30 ...
Page 37: ...2 Operating the MSD To view MSD analyzer temperature and vacuum status 37 ...
Page 39: ...2 Operating the MSD To set monitors for MSD temperature and vacuum status 39 ...
Page 41: ...2 Operating the MSD To set the MSD analyzer temperatures 41 ...
Page 43: ...2 Operating the MSD To set the interface temperature from the ChemStation 43 ...
Page 51: ...2 Operating the MSD To remove the MSD covers 51 Upper cover Lower cover ...
Page 92: ...92 ...
Page 105: ...4 Maintaining the MSD To drain the foreline pump 105 Fill cap Drain plug Pump motor ...
Page 113: ...4 Maintaining the MSD To separate the MSD from the GC 113 ...
Page 121: ...4 Maintaining the MSD To reconnect the MSD to the GC 121 ...
Page 141: ...4 Maintaining the MSD To lubricate the side plate O ring 141 Side plate O ring ...
Page 159: ...4 Maintaining the MSD To remove a filament 159 Filament 2 Filament 1 ...
Page 161: ...4 Maintaining the MSD To reinstall a filament 161 Filament 2 Filament 1 ...
Page 210: ...210 ...
Page 214: ...214 ...
Page 232: ...232 7 Analyzer Analyzer heaters and radiators ...
Page 280: ...280 ...
Page 294: ...294 Index ...
Page 296: ...294 Chapter ...
Page 297: ...H Manual Part Number G1099 90027 Copyright 1998 Hewlett Packard Printed in USA 11 98 ...