background image

HPE FlexNetwork 5120 SI Switch Series 

Installation Guide 

Part number: 5998-8481a

 

Document version: 6W100-20170303

 

Summary of Contents for 5120 SI Series

Page 1: ...HPE FlexNetwork 5120 SI Switch Series Installation Guide Part number 5998 8481a Document version 6W100 20170303 ...

Page 2: ... and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterpris...

Page 3: ...ation 16 Accessing the switch for the first time 17 Setting up the configuration environment 17 Connecting the console cable 17 Console cable 17 Connecting the console cable 17 Setting terminal parameters 18 Powering on the switch 18 Setting up an IRF fabric 19 IRF fabric setup flowchart 19 Planning IRF fabric setup 20 Planning IRF fabric size and the installation site 20 Identifying the master sw...

Page 4: ...pendix B FRUs and compatibility matrixes 33 SFP transceiver modules and SFP Stacking Kit 33 Appendix C Ports and LEDs 35 Ports 35 Console port 35 10 100 1000Base T Ethernet port 35 SFP port 35 LEDs 35 Power LED 36 RPS status LED 36 Port mode LED 36 10 100 1000Base T Ethernet port LED 37 1000Base X SFP port LED 38 Document conventions and icons 39 Conventions 39 Network topology icons 40 Support an...

Page 5: ...0 8G SI Switch Series Product code RMN HPE description JG310B BJNGA AD0007 HPE 5120 8G PoE 65W SI Switch JG309B BJNGA AD0008 HPE 5120 8G PoE 180W SI Switch Safety recommendations To avoid any equipment damage or bodily injury caused by improper use read the following safety recommendations before installation Note that the recommendations do not cover every possible hazardous condition Before clea...

Page 6: ...tion and ESD and bring problems including loose captive screws and circuit failure High temperature can accelerate the aging of insulation materials and significantly lower the reliability and lifespan of the switch For the temperature and humidity requirements see Appendix A Chassis views and technical specifications Cleanliness Dust buildup on the chassis might result in electrostatic adsorption...

Page 7: ...with protection earth PE to filter interference from the power grid Keep the switch far away from radio transmitting stations radar stations and high frequency devices Use electromagnetic shielding for example shielded interface cables when necessary Laser safety The switch is Class 1 laser device WARNING Do not stare into any fiber port when the switch has power The laser light emitted from the o...

Page 8: ...E 370W SI JD323A 1 U mounting bracket kit including one pair of mounting brackets and eight M4 countersunk screws Optional 5120 8G PoE 65W SI 5120 8G PoE 180W SI N A M6 screw and floating nut User supplied All 5120 SI switches 5185 9292 Grounding cable with one ring terminal 1 5120 16G SI 5120 24G SI 5120 48G SI 5120 8G PoE 65W SI 5120 8G PoE 180W SI 5184 6729 Grounding cable with two ring termina...

Page 9: ...5 Product code Description Quantity Applicable models 5184 6719 Console cable 1 All 5120 SI switches 5184 7298 Rubber pads 1 All 5120 SI switches ...

Page 10: ...w Installing the switch in a 19 inch rack Figure 2 shows the general procedure for installing the switch in a 19 inch rack Figure 2 Install the switch in a 19 inch rack Start Install the switch to the specified position Connect the ground wire Connect the power cord Verify the Installation Power on the switch Operates normally Power off the switch Troubleshoot Yes No End Install the transceivers a...

Page 11: ...nting see Figure 8 Mid mounting see Figure 9 Rear mounting see Figure 10 5120 48G SI Front mounting see Figure 8 Rear mounting see Figure 10 Figure 3 Mounting brackets 1 Holes for attaching to a rack by using M6 screws 2 Holes for attaching to the switch chassis Attaching the mounting brackets to the switch chassis 1 Identify the correct mounting position see Table 6 2 Align the round holes in one...

Page 12: ... Front panel Figure 5 Rear mounting position 5120 16G SI 5120 24G SI 1 Front panel Figure 6 Front mounting position 5120 8G PoE 180W SI 5120 8G PoE 65W SI 1 Front panel Figure 7 Rear mounting position 5120 8G PoE 180W SI 5120 8G PoE 65W SI 1 Front panel 1 1 1 1 ...

Page 13: ...good skin contact and is reliably grounded 2 Verify that the rack is reliably grounded and can support the weight of the switch chassis and all its accessories 3 Verify that the mounting brackets have been secured to the switch chassis 4 Install cage nuts user supplied in the mounting holes in the rack posts 5 One person holds the switch chassis and aligns the oval holes in the brackets with the m...

Page 14: ...the rack shelf slide the switch to an appropriate location and attach the switch to the rack with the mounting brackets Figure 11 Mounting the switch in a rack 5120 16G SI 1 Front panel 2 Rear panel Figure 12 Mounting the switch in a rack 5120 24G PoE 370W SI 1 2 1 ...

Page 15: ...ry cloth 3 Attach the rubber feet to the four round holes in the chassis bottom 4 Place the switch with upside up on the workbench NOTE Ensure good ventilation and 10 cm 3 9 in of clearance around the chassis for heat dissipation Avoid placing heavy objects on the switch Grounding the switch Grounding the switch with a grounding strip If a grounding strip is available at the installation site conn...

Page 16: ...ing sign 2 Grounding hole 3 Ring terminal 4 Grounding cable 5 Grounding screw 4 Remove the hex nut of a grounding post on the grounding strip 5 Cut the grounding cable as appropriate for connecting to the grounding strip 6 Make the connector for connecting to the grounding strip If a ring terminal is available peel 5 mm 0 20 in of insulation sheath by using a wire stripper and insert the bare meta...

Page 17: ... site has no grounding strips but earth ground is available hammer a 0 5 m 1 64 ft or longer angle iron or steel tube into the earth ground to serve as a grounding conductor The dimensions of the angle iron must be at least 50 50 5 mm 1 97 1 97 0 20 in The steel tube must be zinc coated and its wall thickness must be at least 3 5 mm 0 14 in Weld the yellow green grounding cable to the angel iron o...

Page 18: ...nal The ground contact in the power outlet is securely connected to the ground in the power distribution room or on the AC transformer side The power cord is securely connected to the power outlet NOTE If the ground contact in the power outlet is not connected to the ground report the problem and reconstruct the grounding system Figure 17 Grounding through the PE wire of the AC power cord 1 Three ...

Page 19: ...o the AC input power receptacle on the switch Figure 18 uses a 5120 24G SI switch for illustration 3 Connect the other end of the AC power cord to the AC power outlet Figure 18 Connecting the AC power cord to the 5120 24G SI switch Connecting the switch to a 52 to 55 VDC output RPS This section applies to the 5120 24G PoE 370W SI switch To connect these switches to the RPS that provides 52 to 55 V...

Page 20: ...o 55 RPS receptacle Verifying the installation After you complete the installation verify that There is enough space for heat dissipation around the switch and the rack or workbench is stable The grounding cable is securely connected The correct power source is used The power cords are correctly connected All the interface cables are cabled indoors If any cable is routed outdoors verify that the s...

Page 21: ...nsole cable is an 8 core shielded cable with a crimped RJ 45 connector at one end for connecting to the console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on the console terminal Figure 21 Console cable Main label 1 8 B side B Pos 9 Pos 1 A side A Connecting the console cable To connect a terminal for example a PC to the switch 1 Plug the DB 9...

Page 22: ...Data bits 8 Parity None Stop bits 1 Powering on the switch Before powering on the switch verify that the following conditions are met The power cord is correctly connected The input power voltage meets the requirement of the switch The console cable is correctly connected The configuration terminal a PC for example has started and its serial port settings are consistent with the console port setti...

Page 23: ...device for flattened network topology and high availability scalability and manageability IRF fabric setup flowchart Figure 22 IRF fabric setup flowchart Connect grounding cables and power cords Configure basic IRF settings Connect the physical IRF ports End Power on the switches Switches elected as slaves reboot and the IRF fabric is established automaticlly Plan IRF fabric setup Install IRF memb...

Page 24: ... of required IRF member switches depending on the user density and upstream bandwidth requirements The switching capacity of an IRF fabric equals the total switching capacities of all member switches NOTE As your business grows you can plug a switch into an IRF fabric to increase the switching capacity without any topology change or replacement Identifying the master switch and planning IRF member...

Page 25: ... it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch You can bind several physical ports to an IRF port to create an aggregate IRF link for increased bandwidth and availability NOTE Figure 23 and Figure 24 show the topologies of a 5120 24G SI IRF fabric The IRF port connection...

Page 26: ... pair cables SFP transceiver modules and optical fibers or SFP Stacking Kit cables to connect the 5120 SI switches for IRF connections As a best practice use Gigabit SFP ports and HPE 3600 Switch SFP Stacking Kit cables for IRF connection Figure 25 shows two IRF connection schemes and uses Gigabit SFP ports and HPE 3600 Switch SFP Stacking Kit cables for IRF connection All these schemes use a ring...

Page 27: ...e IRF fabric to verify the configuration To verify the basic functionality of the IRF fabric after you finish configuring basic IRF settings and connecting IRF ports 1 Log in to the IRF fabric through the console port of any member switch 2 Create a Layer 3 interface assign it an IP address and make sure the IRF fabric and the remote network management station can reach each other 3 Use Telnet web...

Page 28: ... an RPS input failure has occurred Verify the following items The switch is securely connected to the RPS The RPS is correctly working The operating temperature of the switch is in the normal range and the power supply has good ventilation Over temperature can cause the power supply to stop working and enter the protection state Concurrent RPS and AC inputs 1 If the power LED is off the AC power s...

Page 29: ... switch is powered on If the setup is incorrect the configuration terminal would display nothing or garbled text No terminal display If the configuration terminal displays nothing after the switch is powered on verify the following items The power supply is supplying power to the switch The console cable is correctly connected The console cable has no problem and the terminal settings are correct ...

Page 30: ...to sensing Ethernet port 2 1000Base X SFP port 3 Console port 4 Port LED 5 Power LED Power Figure 28 Rear panel 1 AC input power receptacle 2 Grounding screw 5120 24G SI Figure 29 Front panel 1 10 100 1000Base T auto sensing Ethernet port 2 1000Base X SFP port 3 Console port 4 Port LED 5 Power LED Power 1 2 3 4 5 1 2 1 2 3 4 5 ...

Page 31: ...ED 3 Console port 4 Power LED Power 5 1000Base X SFP port 6 1000Base X SFP port LED Figure 32 Rear panel 1 AC input power receptacle 2 Grounding screw 5120 8G PoE 65W SI Figure 33 Front panel 1 10 100 1000Base T auto sensing Ethernet port 2 Port LED mode switching button 3 Port LED 4 Power LED Power 5 Port mode LED 6 Console port 7 1000Base X SFP port 1 2 6 1 2 3 4 5 1 2 2 3 1 4 5 7 6 ...

Page 32: ...E 180W SI Figure 35 Front panel 1 10 100 1000Base T auto sensing Ethernet port 2 Port LED mode switching button 3 Port LED 4 Power LED Power 5 Port mode LED 6 Console port 7 1000Base X SFP port Figure 36 Rear panel 1 AC input power receptacle 2 Grounding screw 2 1 2 3 1 4 5 7 6 2 1 ...

Page 33: ...Ethernet port 2 Port LED mode switching button 3 RPS status LED RPS 4 Port LED 5 Power LED Power 6 Port mode LED 7 Console port 8 1000Base X SFP port Figure 38 Rear panel 1 DC receptacle 2 Screw hole of the plug 3 AC input power receptacle 4 Grounding screw 8 7 6 1 2 3 4 5 2 3 4 1 ...

Page 34: ...Chassis Console ports 10 100 1000Base T auto sensing Ethernet ports 1000Base X SFP ports Interafce card slots 5120 16G SI 1 16 4 N A 5120 24G SI 1 24 4 N A 5120 8G PoE 180W SI 1 8 PoE 1 N A 5120 8G PoE 65W SI 1 8 PPoE 1 N A 5120 24G PoE 370W SI 1 24 PoE 4 N A 5120 48G SI 1 48 4 N A Environmental specifications Chassis Operating temperature Relative humidity All chassis 0 C to 45 C 32 F to 113 F 10...

Page 35: ... consumption specifications for non PoE switches Chassis Minimum power consumption Maximum power consumption 5120 16G SI 11 9 W 25 1 W 5120 24G SI 13 4 W 31 5 W 5120 48G SI 25 7 W 59 8 W Power consumption specifications for PoE switches Chassis Maximu m PoE power per port Total PoE output Minimum power consumption Maximum power consumption including total PoE output 5120 8G PoE 180W SI 30 W 180 W ...

Page 36: ...32 Chassis Built in fans 5120 16G SI 5120 24G SI 5120 48G SI 1 5120 8G PoE 180W SI 3 5120 24G PoE 370W SI 6 ...

Page 37: ...duct code Module description Central wavelength nm Cable fiber diameter µm Multimode fiber modal bandwidth MHz km Maximum transmissio n distance JD118B HP X120 1G SFP LC SX Transceiver 850 50 125 500 550 m 1804 46 ft 400 500 m 1640 42 ft 62 5 125 200 275 m 902 23 ft 160 220 m 721 78 ft JD119B HP X120 1G SFP LC LX Transceiver 1310 9 125 N A 10 km 6 21 miles 50 125 500 400 550 m 1804 46 ft 62 5 125 ...

Page 38: ...er modal bandwidth MHz km Maximum transmissio n distance JD089B HP X120 1G SFP RJ45 T Transceiver N A Category 5 twisted pair N A 100 m 328 08 ft JD324B HPE 3600 Switch SFP Stacking Kit N A UTP STP N A 1 5 m 4 92 ft IMPORTANT You must use the transceiver modules coded JD098B and JD099B in pairs ...

Page 39: ...on program 10 100 1000Base T Ethernet port Table 9 10 100 1000Base T Ethernet port specifications Item Specification Connector type RJ 45 Interface standard 10 Mbps half full duplex 100 Mbps half full duplex 1000 Mbps full duplex MDI MDI X auto sensing Max transmission distance 100 m 328 08 ft Transmission medium Category 5 or above twisted pair cable Standards IEEE 802 3i 802 3u 802 3ab SFP port ...

Page 40: ...0 24G PoE 370W SI switch has one RPS status LED on its front panel to show the operating status of the RPS DC input Table 12 RPS status LED description LED mark Status Description RPS Steady green The RPS DC input is normal Off The RPS unit is not connected or the RPS DC input is abnormal Port mode LED The 5120 8G PoE 65W SI 5120 8G PoE 180W SI and 5120 24G PoE 370W SI switches have a port mode LE...

Page 41: ... Mbps Off No link is present on the port Table 15 Ethernet port LEDs description 5120 16G SI 5120 24G SI LED Status Description Green On The port is operating at 1000 Mbps Fast flashing The port is sending or receiving data at 1000 Mbps Off The port has no link or is not operating at 1000 Mbps Yellow On The port is operating at 10 100 Mbps Fast flashing The port is sending or receiving data at 10 ...

Page 42: ...utput power on the port Off The port is not supplying power Yellow On The device attached to the port is not a powered device or a PoE failure has occurred Off The port is supplying power normally or not supplying power 1000Base X SFP port LED Table 17 1000Base X SFP port LEDs description Status Description Steady green The port is operating at 1000 Mbps Flashing green The port is sending or recei...

Page 43: ...st one x y Asterisk marked square brackets enclose optional syntax choices separated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field name...

Page 44: ... Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a wireless terminator unit Represents a wireless terminator Represents a mesh access point Represents omnidirectional signals Represents directional signals Represents a security product such as a firewall UTM multiservice security gatewa...

Page 45: ...s provide a mechanism for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates go to either of the following Hewlett Packard Enterprise Support Center Get connected with updates page www hpe com support e updates Software Depot website www hpe com support softwaredepot To view and u...

Page 46: ...nterprise authorized service provider will determine whether a repair can be accomplished by CSR For more information about CSR contact your local service provider or go to the CSR website www hpe com support selfrepair Remote support Remote support is available with supported devices as part of your warranty Care Pack Service or contractual support agreement It provides intelligent event diagnosi...

Page 47: ...earth ground 13 Grounding the switch with a grounding strip 11 I Identifying physical IRF ports on the member switches 22 Identifying the master switch and planning IRF member IDs 20 Installation accessories XE installing accessories XE accessories needed for installation 4 Installation tools 3 Installing the switch in a 19 inch rack 6 IRF fabric setup flowchart 19 L Laser safety 3 LEDs 35 M Mount...

Page 48: ...44 SFP port 35 SFP transceiver modules and SFP Stacking Kit 33 T Technical specifications 30 Temperature humidity 2 V Verifying the installation 16 W Websites 42 ...