Power Requirements
Input Voltage (VAC)
100 - 240 VAC
Frequency (Hz)
50 - 60
Component
Idle
(watts / BTU/hr)
Transactional
(watts / BTU/hr)
Node Pair (7200 or 7400), no drives, no
add-on host adapters
236 / 803
398 / 1357
4-port 8Gb/sec Fibre Channel Adapter
24 / 81.7
32.6 / 111
2-port 10Gb/sec iSCSI/FCoE Adapter
34 / 115.8
40 / 136.4
HP M6710 2.5 inch 2U SAS Drive Enclosure,
no drives
150 / 512 (average)
150 / 512 (average)
HP M6720 3.5 inch 4U SAS Drive Enclosure,
no drives
164 / 559 (average)
164 / 559 (average)
300GB 15K Small Form Factor HDD
6.2 / 21.1
8.0 / 27.3
450GB 10K Small Form Factor HDD
3.7 / 12.6
6.3 / 21.5
600 GB 10K Small Form Factor HDD
4.1/14
6.3/21.5
900GB 10K Small Form Factor HDD
4.8 / 16.4
6.2 / 21.1
1 TB 7.2k Small Form Factor HDD
2.95/21.2
3.84/
2TB 7.2K Large Form Factor NL HDD
7.5 / 25.6
10.6 / 36.1
3TB 7.2K Large Form Factor NL NDD
8.5 / 28.9
11.8 / 40.2
100GB SLC SSD
1.4 / 4.8
3.9 / 13.3
200GB SLC SSD
1.4 / 4.8
3.9 / 13.3
400GB MLC SSD
2.2 / 7.5
3.7 / 12.6
Environmental Specifications
Operating Temperature
41° to 104° F (5° to 40° C) - Reduce rating by 1° F for each 1000 ft altitude
(1.8° C/1,000 m)
Shipping Temperature
32° to 140° F (0° to 60° C)
Altitude (ft/m) max.
10,000 ft / 3,048 m
Shipping Altitude (ft/m) max.
40,000ft/ 12,192 m
Humidity
10% to 90% non condensing
Shipping Humidity
10% to 90% non condensing
Operating Vibration
0.25 G, Sine, 5-500 Hz, 0.1 Grms, Random 10-100Hz
Non-operating Vibration
0.5 G, 5 - 500 Hz, Sine
Operating Shock
2 G, 11ms, half-sine
Non-operating Shock
10 G, 11ms, half-sine
Maximum Air Flow
Storage Base and Upgrade Node Pair - 109 CFM per enclosure
M6710 Drive Enclosure - 105 CFM
M6720 Drive Enclosure - 109 CFM
Electromagnetic Compatibility
CISPR 22:2008/ EN55022:2010 Class A
CISPR 24:2010/ EN 55024:2010
QuickSpecs
HP 3PAR StoreServ 7000 Storage
Technical Specifications
DA - 14433 North America — Version 18 — January 17, 2014
Page 32