Calibration Record

Manufacturer

Hewlett Packard

Model No.
Contract No.
Serial No.

Output connection:

X

Balanced

Unbalanced

All measurements to Hewlett Packard Model 334A Distortion Analyzer
Load Resistance:

600

Ohms

Test

Relative

Frequency

% Harmonic

Output

(Hz)

Distortion

(dB #)

5

**

10

**

20
50

100
200
400

1,000
2,000
5,000

10 kHz

12.5 kHz

15 kHz
20 kHz
30 kHz
50 kHz
75 kHz

100 kHz
200 kHz
400 kHz
750 kHz

*

*

1 MHz

*

*

1.25 MHz

*

*

2 MHz

*

*

4 MHz

*

*

Notes:

#   Output flatness measured relative to 400 Hz.     Zero

3.00

volts

*   Denotes value beyond the range of the instrument under test.
**  Denotes measurement limited by noise or capabilities of measuring instrument.

Maximum output level:

No load output voltage @ 400 Hz

20.00

volts

Loaded output

10.00

volts

at

600

ohms

0.17

watts

Date:

Remarks/Repairs:

**

Meter damping was not sufficient

for accurate reading.

Technician:

Test Conditions

Results

200 CD

Wireless Products Company 

 16 Round Pond Lane, Sag Harbor, NY 11963

Tel.: (631) 725-4400 Fax.: (631) 725-2223 E-mail: [email protected]