background image

GB

Thank you for choosing a Hozelock quality product, you can 

be assured of many years of reliable service from this product.

INSTALLATIoN &  

oPErATINg INSTrUCTIoNS

READ THESE INSTRUCTIONS CAREFULLY 

BEFORE ATTEMPTING INSTALLATION.
FAILURE TO OBSERVE THE FOLLOWING 

NOTICES MAY RESULT IN INJURY, PRODUCT DAMAGE OR 

LOSS OF FISH.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
This Hozelock Cyprio Bioforce revolution is a new concept in 

easy maintenance water filtration for garden ponds.
It is:
• Compact and efficient
• Easy to install.
• Trouble free to clean and maintain.
• Can be sited almost anywhere.
Used with the appropriate pond pump, it will improve water 

clarity, remove unwanted solid matter from the pond and 

convert dissolved organic and chemical fish waste into 

harmless compounds.

Attention: UV Caution

This appliance contains a UV-C emitter. Unintended use of 

the appliance or damage to the housing may result in the 

escape of dangerous UV-C radiation. UV-C radiation may, 

even in little doses, cause harm to the eyes and skin. The lamp 

is fitted with an interlock that will turn the lamp off in the 

event that the electrical housing is opened.
When switched on, the lamp can be checked for operation by 

looking for a bluish glow from UV indicator lens. Do not run 

the product dry.
Warning: Do not attempt to operate the UV-C emitter 

when it is removed from the appliance housing.

Important

The appliance is not intended for use by persons  

(including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play 

with the appliance. If this appliance is obviously damaged it 

must not be operated.
(Australia & NZ only). This appliance is not intended for use 

by young children or infirm persons unless they have been 

adequately supervised by a responsible person to ensure that 

they can use the appliance safely. Young children should be 

supervised to ensure that they do not play with the appliance.

Warning:  

Safety & Electrical Connections

1.1 

WARNING: ALWAYS UNPLUG OR DISCONNECT ALL 

APPLIANCES IN THE POND FROM THE ELECTRICITY 

SUPPLY BEFORE PUTTING YOUR HANDS IN THE 

WATER WHILST EQUIPMENT IS BEING INSTALLED, 

REPAIRED, MAINTAINED OR HANDLED.

1.2  This filter has been designed for the use with garden 

ponds only. Do not use this filter for any other use  

(i.e. do not use this filter in swimming pools, etc). Using 

the product for any other application may result in 

injury or product damage.

1.3  Appliances that are obviously damaged must not be 

operated.

1.4  The clear tube inside the unit is made from quartz 

glass and care should be taken during installation and 

maintenance. We recommend the use of eye protection 

and suitable gloves.

1.5  Your Bioforce revolution filter is weatherproof but not 

submersible. Position the unit upright near the pond 

but not where it can fall into the water or where the 

ground can become waterlogged (See the section, 

“Installation”).

1.6  Important: This product is supplied with 5m of 3-core 

electric cable . It is designed to be permanently wired 

to the mains supply. For connection to the mains 

supply use only 3-core cable (ref Ho5 rN-F). This has 

a minimum copper cross-section of 0.75mm2 with 

Polycloroprene-rubber insulation.

 

The termination to the mains supply should be:

• Permanent.
• Inside a dry weatherproof enclosure.
• Through a double pole switched fused spur to BS 3676.
• Fitted with a 3 or 5 amp fuse.

1.7 WARNING: This appliance MUST be earthed and it 

is essential that the connections are made using the 

following code:

• BROWN - live
• BLUE - neutral
• GREEN/YELLOW - earth.

1.8  Exposed cable runs should be sensibly positioned and 

protected by armoured conduit, especially if there is a 

risk of contact with gardening equipment such as forks 

and lawnmowers, or children and domestic animals.

1.9  A 30mA maximum residual Current Device (rCD) 

MUST be fitted to the mains supply.

1.10  Permanent installations to the mains supply (hard 

wiring), must conform to the national and local wiring 

regulations. If in any doubt about wiring to the mains 

supply, consult a qualified electrician or local electricity 

authority.

1.11  Never use the mains supply cable or cleaning handle 

to lift or move the filter, as this may cause damage. 

If the filter needs to be moved, the product should be 

switched off and drained of water first. Then lift the 

product by gripping the area where the lid is clamped 

to the main vessel.

1.12  Never sit or lean on the cleaning handle! (Fig. 4).

Summary of Contents for 1352

Page 1: ...1352 1353 1354 Bioforce Revolution 6 9 14000 www hozelock com 2 Year guarantee Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 www hozelock com 33852 000 ...

Page 2: ...ical Housing b Lid assembly c UV lamp indicator lens d Cleaning Handle Knob e Cleaning Handle f Diverter Valve g Cleaning Fingers Yellow h UV Shroud i Foam Bucket j Cypricube Foam k Bio media l Vessel o ring seal m Filter Vessel n Lid Clamp o Bio trumpet p Hosetail Nut q Lever ...

Page 3: ...ECT ALL APPLIANCES IN THE POND FROM THE ELECTRICITY SUPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED REPAIRED MAINTAINED OR HANDLED 1 2 This filter has been designed for the use with garden ponds only Do not use this filter for any other use i e do not use this filter in swimming pools etc Using the product for any other application may result in injury or product ...

Page 4: ...h the greater the demands on the filtration system In hot climates ie South Africa the Condition Factor is 35 In temperate climates ie Southern Europe the Condition Factor is 15 In a Northern European climate ie most areas of Great Britain the Condition Factor is 0 EXAMPLE You have a 2200 litre goldfish pond 0 75m deep Condition Factor 25 You live in London a Northern European climate Condition Fa...

Page 5: ...ur filter the excavation should be firmly back filled with compacted sand to support the unit If you choose this type of installation you should leave a minimum of a 50mm gap between the clamp and ground level ensuring it is easily removable for annual maintenance 3 4 Using small bore hoses leads to excessive restriction of the water flow The larger the diameter of hose that you use the better the...

Page 6: ...an flow through the foam and cleaning becomes necessary 6 1 Switch off the pump at the mains 6 2 Connect a suitable length of hose to the waste outlet Fig 10 iii using the hosetail provided and a hoseclip The end of the waste hose can positioned above a drain or over a flowerbed The waste water makes excellent fertiliser 6 3 Wind the handle several times We recommend several revolutions in both cl...

Page 7: ... reflector plate and push the black cap on to the end of the lamp 7 1 9 Slide the quartz tube down over the lamp Ensure that the two o rings at the base of the quartz tube are clean and free from debris 7 1 10 Slide the locking collar down over the quartz tube and screw down You should screw down until the stop of the locking collar hits the stop of the housing so that the collar cannot be screwed...

Page 8: ...ucket is correctly positioned to allow easy location of the lid 21 7 3 8 Fill the foam bucket with the recommended amount of replacement Cypricube foam Don t worry if the new dry foam cubes take up a little more space when they are new Ensure no foam falls down the central hole into the bio trumpet area Never squash down your foam to fit more in The dry foam should be loosely added and should not ...

Page 9: ...s not cover loss of water clarity when blanketweed as opposed to greenwater algae is the cause Hozelock Cyprio 2 Year Guarantee If this Bioforce Revolution excluding Lamp becomes unserviceable within 2 years of the date of purchase it will be repaired or replaced at our option free of charge unless in our opinion it has been damaged Liability is not accepted for damage due to accident improper ins...

Page 10: ......

Page 11: ......

Page 12: ...Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 www hozelock com 33852 000 ...