NOTE:
Smaller diameter hoses 13mm (
1
/
2
”)
and 19mm (
3
/
4
”) can be used by fitting an
outlet adaptor either directly on the
chamber of the pump or ‘T’ Piece Adaptor.
2. Route the hose back to the waterfall.
NON-SUBMERSIBLE
INSTALLATIONS
-
5500 ONLY
1. Cascade pumps can be operated out of the
pond. In this case the pump should ideally
be positioned below the water level to
avoid having to re-prime every time the
pump is started (see fig. 2). If the pump is
not positioned below the water level, a
non-return valve (not supplied) should be
fitted to the end of the inlet hose left in the
pond.
2. Remove the filter from the pump.
3. Fit a suitable length of 38mm (1
1
/
2
”) bore
hose on to the inlet boss of the pump using
a suitable worm-drive clip.
4. Connect a hose to the outlet of the pump
for the waterfall, as previously described.
5. To prime the pump create a “U” loop with
the hose ends and pour water down the
waterfall outlet hose until the system is full.
(If a non-return valve is fitted place the
suction end straight into the pond making
sure air does not enter).
NOTE:
A suitable filter should be fitted to
the inlet hose to prevent dirt, debris and
small fish being sucked into the inlet hose.
6. Route the outlet hose to the waterfall.
MAINTENANCE
The Hozelock Cyprio range of Cascade pumps
have been designed to allow fast, easy
maintenance. As with all pumps of its kind
occasionally it will become necessary to clean
the inlet filter and fountain head spray ring.
ALWAYS ISOLATE ELECTRICITY SUPPLY.
CAUTION: PUMPS BECOME HOT. ALLOW TO
COOL IN WATER BEFORE DISMANTLING
FOUNTAIN HEAD
1. Place a coin or similar in the slot and gently
lever off the fountain head.
2. Rinse in clean water and reassemble.
FILTER
1. Holding the pump in one hand, press down
the retaining clip on the filter cover and
pull away from the main body.
2. Wash/rinse with clean water - re-assemble.
If the pump is to be stored over winter or
needs dismantling for any reason, proceed in
the following manner (see fig. 3).
1. Remove the filter as described above.
2. Release the pump chamber by rotating it
clockwise until the three bayonet lugs are
clear from the sockets.
3. Gently pull the pump chamber squarely
away from the main body.
4. Pull the rotor assembly out of the pump
body. If necessary a screwdriver can be used
in the slots provided to lever the rotor
assembly away from the pump body.
(Further dismantling of rotor is unnecessary).
5. Clean out all components in clean water.
DO NOT USE DETERGENTS OR OTHER
CHEMICAL CLEANERS.
6. Place the rotor assembly into the pump
body ensuring the four holes in the front
bearing plate locate correctly over the four
lugs on the motor body. (fig. 3).
7. Re-fit the pump chamber, and filter cover.
HOZELOCK CYPRIO 3 YEAR
GUARANTEE
If this pump becomes unserviceable within 3
years of the date of purchase it will be
repaired or replaced at our option free of
charge, unless in our opinion it has been
damaged or misused. To obtain the benefits of
this guarantee firstly contact Hozelock Cyprio
Consumer Services who may request that the
pump is sent along with proof of purchase
direct to the address shown:-
DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.
IF YOUR CASCADE PUMP FAILS
TO OPERATE
If you live in a hard water area, calcium build
up between the bearings may cause them to
seize. The bearings may be freed by removing
the rotor assembly from the pump and placing
it in a de-scaling solution. After this time the
front bearing plate (see fig 3) should freely
rotate. Replace rotor assembly as previously
described. (See maintenance No. 6).
SPARE PARTS
(see fig. 4). Contact Helpline on
0870 850 1959.
Hozelock Cyprio
Midpoint Park, Birmingham B76 1AB.
England.
Tel: +44 (0)870 850 1959
www.hozelock.com
The Aquatics Division of Hozelock Group
1
2
3
4
7
6
5
9
8
4
1
2
3
FAULT FINDING
IMPORTANT - PLEASE
KEEP THIS SECTION FOR
REFERENCE
LOW FLOW FROM PUMP
1. Ensure filter is clean.
2. A small diameter
outlet pipe will
restrict outlet flow.
3. Clear any blockages
and adjust stem flow
control.
4. Check bearings for
calcium build-up.
NO FLOW FROM PUMP
1. Check power supply is
on.
2. Check fuse and
wiring.
3. Impeller assembly
jammed - check rotor
for damage and
impeller for wear.
4. Ensure filter is clean.
5. Thermal fuse tripped.
POOR FOUNTAIN
DISPLAY
1. Clean Fountain Head
(see maintenance).
Hozelock Cyprio
Midpoint Park, Birmingham B76
1AB. England.
Tel: +44 (0)870 850 1959
www.hozelock.com
The Aquatics Division of Hozelock Group
33637-001
PLEASE NOTE:
Do not
dispose of in
household
waste
Part Number
5500 7000
1 ’O’ Ring Seal
Z31965
Z31965
2 Rotor Assembly
Z31996
Z31997
3 Pump Chamber
Z31846
Z31846
4 Strainer Cage
Z31825
Z31925
5 ‘T’ Piece Assembly
Z31135
Z31135
6 3 Tier Fountain Head
Z31185
Z31185
7 2 Tier Fountain Head
Z31195
Z31195
8 Outlet Adaptor Chamber
Z31205
Z31205
9 Outlet Adaptor ‘T’ Piece
Z31215
Z31215