HOZAN HC-33 Instruction Manual Download Page 4

 

Operation 

 

4 

Bring the tip of the HC-33 close to the 
area where color distortion was occurred 
on the cathode ray tube. Once push and 
release the power switch. The power 
damping function will work and off the 
power in a second. 
Repeat the operation or orient the HC-33 
parallel with the tube face.

 

 

 

Plug in the power plug to the wall outlet.

 

● 

For cathode ray tube

 

The same procedure as TV tube.

 

10.02C

 

If your PC monitor is by aperture-mask system, 
after finishing this procedure, sometimes verti-
cal lines appear on the screen by distortion on 
aperture-musk itself receiving repercussion of 
the demagnetizer, but this is not malfunction. In 
case of this, softly hit the side of the monitor set 
to recover.

 

 

Caution

 

Bring the tip of the HC-33 close to the magnetized object. Once push and release 
the power switch. 
It can not be demagnetized enough when used against a tool or a little part. In 
case of this, close the HC-33 and the object as near as possible, then while push-
ing the power switch, gradually pull the HC-33 away from the object approximately 
30cm, and release the switch. 

 

● 

For other objects

 

1-2-12 Saiwaicho, Naniwa-ku, Osaka 556-0021, Japan

 

Tel : +81-6-6567-3111

   

Fa x : +81-6-6562-0024

 