To avoid power de-rating due to an increase in the microinverter internal temperature, do not
expose it to direct sunlight.
To avoid overheating, always make sure the air flow around the inverter is not blocked.
Do not install in places where gasses or flammable substances may be present.
Avoid electromagnetic interference that can compromise the correct operation of electronic
equipment.
When choosing the position of installation, comply with the following conditions:
Install only on structures specifically conceived for photovoltaic modules (supplied by
installation technicians).
Install Microinverter underneath of the photovoltaic modules to make sure it works in
theshadow. If this condition cannot be met, might trigger the inverter production de-rating.
Fig.1 Installation position of microinverter
5.5 Installation Steps
Step 1. Fix Microinverter on the Rail
A) Mark the approximate center of each panel on the frame.
B) Fix the screw on the rail.
C) Hang the microinverter on the screw (shown as picture below), and tighten the screw. The silver
cover side of the Microinverter should be facing the panel.