9. Technical Data
Warning: Be sure to verify the following before installing the Hoymiles Microinverter
System.
Verify that the voltage and current specifications of the PV module match those of the
microinverter.
The maximum open-circuit voltage rating of the PV module must be within the operating
voltage range of the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the
maximum input DC current. But the maximum short-circuit current must be equal to or less
than the maximum input DC short-circuit current.
The output DC power of the PV module is NOT recommended to exceed 1.35 times the
output AC power of the microinverter. Refer to the “Hoymiles Warranty Terms & Conditions”
for more information.
9.1 DC Input
Model
HM-600
HM-600P
HM-700
HM-700P
HM-800
Commonly used module power (W)
Up to 380
(single
panel)
Up to 440
(single
panel)
Up to 500
(single
panel)
Peak power MPPT voltage range (V)
29–48
33–48
34–48
Start-up voltage (V)
22
Operating voltage range (V)
16–60
Maximum input voltage (V)
60
Maximum input current (A)
2 × 11.5
2 × 11.5
2 × 11.5
2 × 11.5
2 × 12.5
Maximum input short-circuit current (A)
2 × 15
Maximum backfeed current to array (A)
0
Number of MPPTs
2
Number of inputs per MPPT
1
9.2 AC Output
Model
HM-600
HM-600P
HM-700
HM-700P
HM-800
Rated output power (VA)
600
625
700
714
800
Rated output current (A)
2.73@220 V
2.61@230 V
2.50@240 V
3.18@220 V
3.04@230 V
2.92@240 V
3.64@220 V
3.48@230 V
3.33@240 V
Nominal output voltage/range (V)
220/180–275
230/180–275
240/180–275
Nominal frequency/range (Hz)
45–55 (under 50 Hz @ 220 V & 230 V)
55–65 (under 60 Hz @ 220 V & 230 V)
Power factor
> 0.99 default
0.8 leading…0.8 lagging
Output current harmonic distortion
< 3%
Maximum units per branch
8@220 V
8@230 V
8@240 V
7@220 V
7@230 V
7@240 V
6@220 V
6@230 V
6@240 V